Gefen EXT-DVIKVM-841DL Switch User Manual


 
9
RMT-8IR REMOTE AND 8X1 KVM SWITCHER CONFIGURATION
How to Resolve IR Code Con icts
In the event that IR commands from other remote controls con ict with the
supplied RMT-8IR remote control, changing the remote channel will alleviate this
issue. The RMT-8IR remote control and the 8x1 DVI KVM DL/SL Switcher both
have banks of DIP (Dual Inline Package) Switches for con guring the remote
channel that both units use to communicate. These settings must exactly match
each other for proper operation.
The DIP Switch bank on the RMT-8IR is located underneath the battery cover.
DIP Switch banks for the 8x1 DVI KVM DL/SL Switcher are located on the
underside of the unit beneath a black piece of metallic tape. One DIP switch
bank (4-switch) is for the adjustment of remote control frequencies and switch
behavior. The other DIP switch (8-switch) is reserved for Gefen use only. DIP
Switches 1 and 2 on the RMT-8IR directly correspond to DIP Switches 1 and 2 on
the 8x1 DVI KVM DL/SL Switcher. Only switches 1 and 2 (of 4 in that bank) are
used for IR Code settings.
Remote Channel 1:
Default
1 2
Remote Channel 2:
1 2
Remote Channel 3:
1 2
Remote Channel 4:
1 2
Left: Picture of the opened rear battery
compartment of the RMT8-IR remote showing
the exposed DIP Switch bank between the
battery chambers.
8x1 DVI KVM DL/SL Switcher
Remote Channel 1:
Default
Remote Channel 4:
1
1
2
2
3
3
4
4
Remote Channel 3:
1
2
3
4
Remote Channel 2:
1
2
3
4