Gossen R2601 Network Card User Manual


 
GOSSEN METRAWATT GMBH 7
Following, the master may only become active again, when
it receives a reply telegram from the addressed equipment and the specified wait time after a reply telegram (t aw) has elapsed, or
the maximum specified response delay time (t
av) has elapsed.
Within a telegram, pauses of limited duration (t zv = character delay time) may occur between 2 character transmissions.
1.5 Time action
Ready to send/receive after turn-on t ber approx. 5 s
Character delay time (R2600 transmitter) t
zvs <3ms
Character delay time (master) t
zvm < 500 ms
Response delay time (R2600 transmitter) 10 ms < t
av <100 ms
Wait time after R2600 response (master) t
aw > 10 ms
Time
Master
sends
Equipment
responds
t
ber
approx. 5 s
t
av
10 ...
100 ms
tzvs
< 3 ms
Master
sends
taw
> 10 ms
t
zvm
< 500 ms