18
CONTINUITY DIAGRAM
Model 927060, 062, 064
Solenoid
NOT ENERGIZED
ENERGIZED
The diagrams below show the various states of connection for electrical components.
The solid lines on switches show continuity.
NOTE: All switches are viewed from the rear.
PTO Switch
Seat Switch
Relay
39
471
DISENGAGED
(down position)
39
471
ENGAGED
(up position)
1
OPERATOR
OFF SEAT
2
1
OPERATOR
ON SEAT
2
87
87A
86 85
30
NOT ENERGIZED
87
87A
86 85
30
ENERGIZED
OFF
M
G
S2
B
S1
A
RUN
M
G
S2
B
S1
A
START
M
G
S2
B
S1
A
Key Switch
(01563700)
OFF ON
Light Switch
(03656800)
Parking Brake Switch
(02777200)
1
2
(03042800)
(01545600)
(02754100)
(03679000)
1
2
ON
OFF
Brake Neutral Switch
1
2
BUTTON DOWN
1
2
BUTTON UP
(03657100)
PA0261