Hand Held Products IT3800 Scanner User Manual


 
2 - 10 IT3800/3900 User’s Guide
RS-232 Word Length: Data Bits, Stop Bits, and Parity
Data Bits
sets the word length at 7 or 8 bits of data per character. If an
application requires only ASCII Hex characters 0 through 7F decimal (text, digits,
and punctuation), select 7 data bits. For applications which require use of the full
ASCII set, select 8 data bits per character. Default = 7.
Stop Bits
sets the stop bits at 1 or 2. Default = 1.
Parity
provides a means of checking character bit patterns for validity.
Default = Even.
* 7 Data, 1 Stop, Parity Even
7 Data, 1 Stop, Parity Mark
7 Data, 1 Stop, Parity None
7 Data, 1 Stop, Parity Odd
7 Data, 1 Stop, Parity Space
7 Data, 2 Stop, Parity Odd
7 Data, 2 Stop, Parity Even
7 Data, 2 Stop Parity None
7 Data, 2 Stop, Parity Mark