Hatco GRAH Printer Accessories User Manual


 
Form No. GRM-0707
14
INSTALLATION
PERMANENT SURFACE MOUNT
Tubular Stand Mounting
Tubular stand mounting permanently attaches the
unit to a countertop or serving table. All wiring may
be concealed within the tubular stand.
Tubular stands are available in non-adjustable
heights from 10"-16" (254-406 mm) or in adjustable
heights from 10"-14" (254-356 mm).
NOTE: Tubular stands are not field retro-fittable.
NOTE: If wiring is to be concealed, a 1" (25 mm)
diameter hole must be provided in the mounting
surface, centered under the leg flange nearest the
electrical wiring hookup.
1. Position the unit upside-down on a flat surface.
2. Units for this application are supplied with the
conduit attached. Conduit should not be
removed.
3. If applicable, route flexible conduit through the
leg opening. Pull the leg up to the underside of
the warmer. (See Figure 15.)
4. Secure legs to warmer using screws supplied.
5. If applicable, route the flexible conduit through
opening in countertop.
6. Secure the legs to the mounting surface.
NOTE: The adjustable legs can be raised or lowered
by turning the locking set screw counterclockwise
one turn with an allen wrench, and then raising or
lowering the unit to the desired height and
retightening the screw. Do not loosen the screw
more than necessary.
NOTE: Two pairs of legs will be needed for
mounting dual units.
Figure 15. Tubular Stand Mounting
Locking
Screw
Covers
Adjustable
Leg
Non-Adjustable Leg
Flexible Conduit