Environment
Temperature
Operating: 0° to 40° C (32° to 104° F)
Non-operating: -25° to 70° C (-13° to 158° F)
Humidity
Operating: 10 to 85 percent non-condensing at 40°C (104°F)
Altitude
Operating: Up to 3000 meters (9842 feet)
Storage: Up to 12 kilometers (39,370 feet)
Shock
Operating: 20 g, 6 ms half-sine
Non-operating: Half sine, 33G 11ms. 3/eg Axis
Vibration
Operating: 0.5 g sine, 0.4 grms random, 5 to 500 Hz
Non-operating: 2.0 g sine, 1.1 grms random, 5 to 500 Hz
Airflow
High speed
20.8 CFM (cu. ft./min)
Low speed
(65%)
15.4 CFM
Power
Maximum output
70 Watts
System power
consumption
70 Watts max, 60 Watts typical
Nominal input voltage
90- 264 VAC, Universal
Input line frequency
47 - 63 Hz
Minimum input voltage
90 VAC
Maximum input voltage
264 VAC
BTU rating
(80%
efficiency)
240 BTU/hr
Inrush current
Maximum of 15 amps for period between 10-150 ms at 50° C (122° F)
© Copyright 2007 Hewlett-Packard Development Company, L.P.
The information contained herein is subject to change without notice.
The only warranties for HP products and services are set forth in the express warranty statements accompanying such
products and services. Nothing herein should be construed as constituting an additional warranty. HP shall not be liable for
technical or editorial errors or omissions contained herein.