HP (Hewlett-Packard) 674786-001 Server User Manual


 
Specifications 91
HP 350 W 4U Factory Integrated Power Supply
Specification Value
Input requirements
Rated input voltage
100 V AC to 240 V AC
Rated input frequency
47 Hz to 63 Hz
Rated input current
6 A
Rated input power
440 W at 100 V AC input
440 W at 200 V AC input
Efficiency
No less than 82% at 100% load
No less than 85% at 50% load
No less than 82% at 20% load
Power supply output
Rated steady-state power
350 W at 100 V AC input
350 W at 200 V AC input
Maximum peak power
400 W at 100 V AC input
400 W at 200 V AC input
Rated output power
350 W
HP 460 W CS Gold Hot-plug Power Supply (92% efficiency)
Specification Value
Input requirements
Rated input voltage
100 V AC to 240 V AC
Rated input frequency
50 Hz to 60 Hz
Rated input current
6 A to 3 A
Rated input power
526 W at 115 V AC input
523 W at 230 V AC input
Power supply output
Efficiency
Not less than 87.5% at 100% load
Not less than 89.5% at 50% load
Not less than 87.5% at 20% load
Rated steady-state power
460 W at 100 V to 120 V AC
input
460 W at 200 V to 240 V AC
input
Maximum peak power
460 W at 100 V to 120 V AC
input
460 W at 200 V to 240 V AC
input
Hot-plug power supply calculations
For hot-plug power supply specifications and calculators to determine electrical and heat loading for the
server, refer to the HP Enterprise Configurator website (http://h30099.www3.hp.com/configurator/).