A Specifications
Table A-1 Specifications
Desktop Dimensions
Height
Width
Depth
14.85 in
6.95 in
16.85 in
37.72 cm
17.65 cm
42.80 cm
Approximate Weight 23.5 lb 10.66 kg
Temperature Range
Operating
Nonoperating
50° to 95°F
-22° to 140°F
10° to 35°C
-30° to 60°C
Relative Humidity (noncondensing)
Operating
Nonoperating (38.7°C max wet bulb)
10-90%
5-95%
10-90%
5-95%
Maximum Altitude (unpressurized)
Operating
Nonoperating
10,000 ft
30,000 ft
3048 m
9144 m
NOTE: Operating temperature is derated 1.0° C per 300 m (1000 ft) to 3000 m (10,000 ft) above sea level; no direct sustained
sunlight. Maximum rate of change is 10° C/Hr. The upper limit may be limited by the type and number of options installed.
Heat Dissipation
Max STD PS
Typical STD PS idle
Max EPA 87/89/85% @ 20/50/100% load PS
Typical EPA 87/89/85% @ 20/50/100% load PS idle
1410 BTU/hr
272 BTU/hr
1255 BTU/hr
238 BTU/hr
356 kg-cal/hr
68 kg-cal/hr
316 kg-cal/hr
59 kg-cal/hr
Power Supply
Operating Voltage Range (STD PS)
1
Operating Voltage Range (EPA 87/89/85% @ 20/50/100% load PS)
Rated Voltage Range (STD PS)
Rated Voltage Range (EPA 87/89/85% @ 20/50/100% load PS)
Rated Line Frequency
115V
90-264 VAC
90-264 VAC
100-240 VAC
100-240 VAC
50-60 Hz
230V
90-264 VAC
90-264 VAC
100-240 VAC
100-240 VAC
50-60 Hz
42 Appendix A Specifications ENWW