A Specifications
Table A-1 Specifications
Desktop Dimensions (in the desktop position)
Height
Width
Depth
3.95 in
13.3 in
14.9 in
10.0 cm
33.8 cm
37.8 cm
Approximate Weight 19 lb 8.6 kg
Weight Supported (maximum distributed load in desktop position) 77 lb 35 kg
Temperature Range
Operating
Nonoperating
50° to 95°F
-22° to 140°F
10° to 35°C
-30° to 60°C
NOTE: Operating temperature is derated 1.0° C per 300 m (1000 ft) to 3000 m (10,000 ft) above sea level; no direct sustained
sunlight. Maximum rate of change is 10° C/Hr. The upper limit may be limited by the type and number of options installed.
Relative Humidity (noncondensing)
Operating
Nonoperating (38.7°C max wet bulb)
10-90%
5-95%
10-90%
5-95%
Maximum Altitude (unpressurized)
Operating
Nonoperating
10,000 ft
30,000 ft
3048 m
9144 m
Heat Dissipation
Max STD PS
Typical STD PS idle
Max EPA 87/89/85% @ 20/50/100% load PS
Typical EPA 87/89/85% @ 20/50/100% load PS idle
1063 BTU/hr
287 BTU/hr
941 BTU/hr
238 BTU/hr
268 kg-cal/hr
72 kg-cal/hr
237 kg-cal/hr
60 kg-cal/hr
Power Supply
Operating Voltage Range (STD PS)
Operating Voltage Range (EPA 87/89/85% @ 20/50/100% load PS)
Rated Voltage Range (STD PS)
Rated Voltage Range (EPA 87/89/85% @ 20/50/100% load PS)
115V
90-264 VAC
90-264 VAC
100-240 VAC
100-240 VAC
230V
90-264 VAC
90-264 VAC
100-240 VAC
100-240 VAC
ENWW 47