HP (Hewlett-Packard) BC1500 Server User Manual


 
Broadcom 5705F 10/100
Broadcom 5705F 10/100Broadcom 5705F 10/100
Broadcom 5705F 10/100
Integrated NIC
Integrated NICIntegrated NIC
Integrated NIC
Network interface
Network interfaceNetwork interface
Network interface
10Base-T/100Base-TX
Compatibility
CompatibilityCompatibility
Compatibility
IEEE 802.3/802.3u compliant
Data transfer method
Data transfer methodData transfer method
Data transfer method
32-bit bus-master PCI
Features
FeaturesFeatures
Features
NIC A WOL enabled and PXE compliant
Network transfer rate
Network transfer rateNetwork transfer rate
Network transfer rate
10Base-T (half-duplex)
10 Mb/s
10Base-T (full-duplex)
20 Mb/s
100Base-TX (half-duplex)
100 Mb/s
100Base-TX (full-duplex)
200 Mb/s
Connector
ConnectorConnector
Connector
Mates into enclosure center wall assembly
Enclosure
EnclosureEnclosure
Enclosure
Dimensions
DimensionsDimensions
Dimensions
Height
HeightHeight
Height
(3U)
5.25 in (13.34 cm)
Width
WidthWidth
Width
19 in (48.26 cm)
Depth
DepthDepth
Depth
27 in (68.58 cm)
Weight
WeightWeight
Weight
(with interconnect
tray)
No blade PCs
No blade PCsNo blade PCs
No blade PCs
59 lb (26.76 kg)
20 blade PCs
20 blade PCs20 blade PCs
20 blade PCs
103 lb (46.7 kg)
Rated input
Rated inputRated input
Rated input
(autosensing)
Voltage
VoltageVoltage
Voltage
Minimum: 90 VAC
Maximum: 264 VAC
Nominal: 100 to 120 VAC or 200 to 240 VAC
Frequency
FrequencyFrequency
Frequency
47 to 63 Hz
Current
CurrentCurrent
Current
11.7 A at 90 VAC
8.5 A at 120 VAC
4.3 A at 240 VAC
Power
PowerPower
Power
1000 W
BTUs
BTUsBTUs
BTUs
Per hour
Per hourPer hour
Per hour
3416
Temperature
TemperatureTemperature
Temperature
1
Operating
OperatingOperating
Operating
50° to 95° F (10° to 35° C)
Shipping, 72 hours
Shipping, 72 hoursShipping, 72 hours
Shipping, 72 hours
-40° to 140° F (-40° to 60° C)
Relative humidity
Relative humidityRelative humidity
Relative humidity
(non-
condensing)
Operating
OperatingOperating
Operating
10% to 90%
Non-operating
Non-operatingNon-operating
Non-operating
10% to 95%
Management
ManagementManagement
Management
Enclosure self recovery
Health logs
Redundant power supply utility
Automatic System Recovery (ASR)
High availability
High availabilityHigh availability
High availability
Redundant hot-plug power supplies
Redundant hot-plug fans
NOTE 1:
NOTE 1:NOTE 1:
NOTE 1:
Operating temperature has an altitude derating of 34° F (1° C) per 1,000 ft (304.8 m). No direct sunlight. Storage
maximum humidity of 95% is based on a maximum temperature of 112° F (45° C). Minimum pressure for storage is 70 KPa.
For more information on CCI power and thermal facility site planning:
http://h30099.www3.hp.com/configurator/calc/Power%20Calculator%20Catalog.xls
QuickSpecs
HP BladeSystem bc1500 Blade PC
HP BladeSystem bc1500 Blade PCHP BladeSystem bc1500 Blade PC
HP BladeSystem bc1500 Blade PC
Technical Specifications
DA - 12390 North America — Version 4 — January 22, 2007