HP (Hewlett-Packard) BK766A Server User Manual


 
Is the enclosure rear fault LED amber?
ActionsPossible ReasonsAnswers
No action requiredFunctioning properly.No
Be sure that the rear power and
UID module is undamaged and
is fully seated.
Contact an authorized service
provider for assistance.
Rear power and UID module might
not be inserted properly, might
have a damaged connector, or
might have failed.
Yes
Is the power on/standby button LED amber?
Possible SolutionsPossible ReasonsAnswer
No action required.System functioning properly.No
Firmly press the power
on/standby button and hold for
approximately three seconds.
Be sure that all components are
fully seated.
Update controller firmware.
Contact an authorized service
provider for assistance.
The power on/standby button
has not been pressed firmly or
held long enough.
The system might have experi-
enced a short. Controller firm-
ware might be corrupted.
The system midplane and/or
power button/LED assembly
might need to be replaced.
Yes
Is the power supply LED amber?
ActionsPossible ReasonsAnswers
Remove and inspect the AC
power cords from both power
supplies and reconnect them.
No action required.
Power cords not connected or
AC power is unavailable.
Power supply functioning prop-
erly.
No
Be sure that the power supply
is undamaged and is fully
seated.
Be sure that all pins on connect-
ors and components are
straight.
Contact an authorized service
provider for assistance.
Power supply might not be inser-
ted properly, might have a
damaged connector, or might
have failed.
Yes
Troubleshooting52