HP (Hewlett-Packard) BV861SB Server User Manual


 
X1600 G2
(SFF front drive
slots)
1
x16
PCI-Express
x8
1
Half length,
half height
2
x8
PCI-Express
x4
5
Full Length,
full height
Occupied by
Smart Array
controller
3
x8
PCI-Express
x4
4
Full Length,
full height
4
x4
PCI-Express
x4
3
Full length,
full height
X1800 G2
1
x8
PCI-Express
x16
7
Full Length,
full height
2
x4
PCI-Express
x8
10
Half Length,
full height
3
x4
PCI-Express
x8
13
Half Length,
full height
Occupied by
SAS Expander
4
x8
PCI-Express
x16
16
Full length,
full height
Occupied by
Smart Array
Controller
5
x4
PCI-Express
x8
20
Half length,
half height
6
x4
PCI-Express
x8
23
Half length,
half height
* Default bus assignment. Inserting cards with PCI bridges may alter the actual bus
assignment number.
Storage Controller
X1400 G2 X1500 G2 X1600 G2 X1800 G2
Controller(s)
HP Smart Array
P212/256MB
Controller with
battery-backed
write cache
(BBWC)
HP Smart Array
P410/256MB
Controller with
BBWC
HP Smart Array
P212/512MB
Controller with
BBWC (LFF front
drive slots)
HP Smart Array
P812/1GB
Controller with
Flash backed write
cache (FBWC) -
(SFF front drive
slots)
HP Smart Array
P812/1GB
Controller with
Flash backed write
cache (FBWC)
RAID
0/1/1+0/5/5+0
6/6+0
0/1/1+0/5/5+0
6/6+0
0/1/1+0/5/5+0
6/6+0
0/1/1+0/5/5+0
6/6+0
Internal SAS connectors
1 2
1 (LFF) 2 (SFF)
2
External SAS connectors
1 0
1 (LFF) 4 (SFF)
4
NOTE:
Smart Array Advanced Pack License (516471-B21) is included to enable RAID 6, 6+0.
QuickSpecs
HP X1000 G2 Network Storage Systems
Standard Features
DA - 13839 North America — Version 11 — December 28, 2012
Page 14