HP (Hewlett-Packard) DL380 Server User Manual


 
750 W (at 200 to 240 VAC)
For 460 W Power Supply:
460 W (at 100 to 120 VAC),
460 W (at 200 to 240 VAC)
Maximum Peak Power
For 1200 W Power Supply:
800 W (at 100 VAC),
900 W (at 120 VAC),
1200 W (at 200 to 240 VAC)
For 750 W Power Supply:
750 W (at 100 to 120 VAC),
750 W (at 200 to 240 VAC)
For 460 W Power Supply:
460 W (at 100 to 120 VAC),
460 W (at 200 to 240 VAC)
System Inlet Temperature
System Inlet TemperatureSystem Inlet Temperature
System Inlet Temperature
Operating
10° to 35°C (50° to 95°F) at sea level with an
altitude derating of 1.0°C per every 305 m
(1.8°F per every 1000 ft) above sea level to a
maximum of 3050 m (10,000 ft), no direct
sustained sunlight. Maximum rate of change is
10°C/hr (18°F/hr). The upper limit may be
limited by the type and number of options
installed.
System performance may be reduced if operating
with a fan fault or above 30°C (86°F).
Non-operating
-30° to 60°C (-22° to 140°F). Maximum rate of
change is 20°C/hr (36°F/hr).
Relative Humidity
Relative HumidityRelative Humidity
Relative Humidity
(non-condensing)
Operating
10 to 90% relative humidity (Rh), 28°C (82.4°F)
maximum wet bulb temperature, non-
condensing.
Non-operating
5 to 95% relative humidity (Rh), 38.7°C
(101.7°F) maximum wet bulb temperature, non-
condensing.
Altitude
AltitudeAltitude
Altitude
Operating
3050 m (10,000 ft). This value may be limited by
the type and number of options installed.
Maximum allowable altitude change rate is 457
m/min (1500 ft/min).
Non-operating
9144 m (30,000 ft). Maximum allowable
altitude change rate is 457 m/min (1500 ft/min).
Acoustic Noise
Acoustic NoiseAcoustic Noise
Acoustic Noise
Listed are the declared A-Weighted sound power levels (LWAd) and declared
average bystander position A-Weighted sound pressure levels (LpAm) when
the product is operating in a 23°C ambient environment. Noise emissions
were measured in accordance with ISO 7779 (ECMA 74) and declared in
accordance with ISO 9296 (ECMA 109).
NOTE:
NOTE: NOTE:
NOTE:
The Listed sound levels apply to standard shipping configurations.
Additional options may result in increased sound levels.
Idle
IdleIdle
Idle
1P SKU
1P SKU1P SKU
1P SKU 2P SKU
2P SKU2P SKU
2P SKU
LWAd
4.1 B 4.7 B
LpAm
22 dBA 28 dBA
Operating
OperatingOperating
Operating
1P SKU
1P SKU1P SKU
1P SKU 2P SKU
2P SKU2P SKU
2P SKU
QuickSpecs
HP ProLiant DL380 Generation 6 (G6)
HP ProLiant DL380 Generation 6 (G6)HP ProLiant DL380 Generation 6 (G6)
HP ProLiant DL380 Generation 6 (G6)
Technical Specifications
DA - 13234 Worldwide — Version 12 — July 13, 2009
Page 48