HP (Hewlett-Packard) DL385 Computer Hardware User Manual


 
System Fans
System FansSystem Fans
System Fans
Hot plug fans ship standard, N+1 fully redundant
(3+1) for 1 processor, (5+1) for 2 processors
NOTE:
NOTE:NOTE:
NOTE:
Processor option kits include 2 additional fans when upgrading to 2 processors.
Operating Systems and
Operating Systems andOperating Systems and
Operating Systems and
Virtualization Software
Virtualization SoftwareVirtualization Software
Virtualization Software
Support for ProLiant
Support for ProLiantSupport for ProLiant
Support for ProLiant
Servers
ServersServers
Servers
Microsoft Windows Server
Red Hat Enterprise Linux (RHEL)
SUSE Linux Enterprise Server (SLES)
Oracle Enterprise Linux (OEL)
VMware
Citrix XenServer
NOTE:
NOTE:NOTE:
NOTE:
For more information on HP's Certified and Supported ProLiant Servers for OS and Virtualization
Software and latest listing of software drivers available for your server, please visit our Support Matrix at:
http://www.hp.com/go/ossupport
and our driver download page
www.hp.com/support/DL385G7
Rack Airflow
Rack AirflowRack Airflow
Rack Airflow
Requirements
RequirementsRequirements
Requirements
Rack 10000 G2 series Cabinets
Rack 10000 G2 series CabinetsRack 10000 G2 series Cabinets
Rack 10000 G2 series Cabinets
The increasing power of new high-performance processor technology requires increased cooling
efficiency for rack-mounted servers. The 10000 G2 Series Racks provide enhanced airflow for maximum
cooling, allowing these racks to be fully loaded with servers using the latest processors.
CAUTION:
CAUTION:CAUTION:
CAUTION:
If a third-party rack is used, observe the following additional requirements to ensure
adequate airflow and to prevent damage to the equipment:
Front and rear doors: If your 42U server rack includes closing front and rear doors, you must
allow 830 square inches (5,350 sq cm) of holes evenly distributed from top to bottom to permit
adequate airflow (equivalent to the required 64 percent open area for ventilation).
Side: The clearance between the installed rack component and the side panels of the rack must be
a minimum of 2.75 inches (7 cm).
CAUTION:
CAUTION:CAUTION:
CAUTION:
Always use blanking panels to fill all remaining empty front panel U-spaces in the rack. This
arrangement ensures proper airflow. Using a rack without blanking panels results in improper cooling
that can lead to thermal damage.
NOTE:
NOTE:NOTE:
NOTE:
For additional information, refer to the Setup and Installation Guide or the Documentation CD
provided with the server, or to the server documentation located in the Support section at the following
URL:
www.hp.com/servers/dl385-g7
.
Rack Kit
Rack KitRack Kit
Rack Kit
Quick deploy rail system provides tool-free support for racks with square or round mounting holes
(including Compaq/HP 7000, 9000, 10000 G2 and HP series), with an adjustment range of 24" - 36".
The ambidextrous cable management arm can be mounted on either the left or right side for improved
cable management.
NOTE:
NOTE:NOTE:
NOTE:
Cable management arm must be removed to access hot-plug power supplies when the cable
management arm is mounted on the right.
NOTE:
NOTE:NOTE:
NOTE:
High Airflow Inserts (High Air Flow Rack Door Insert for the 7142 Rack (single) - PN: 327281-
B21; or High Air Flow Rack Door Insert for the 7142 Rack (6-pack) - PN: 327281-B22) are required to
support the HP ProLiant DL385 in 7000 series racks. The DL385 Cable Management Arm is not
supported on 7000 series racks.
QuickSpecs
HP ProLiant DL385 Generation 7 (G7)
HP ProLiant DL385 Generation 7 (G7)HP ProLiant DL385 Generation 7 (G7)
HP ProLiant DL385 Generation 7 (G7)
Standard Features
DA - 13594 Worldwide — Version 3 — May 7, 2010
Page 11