HP (Hewlett-Packard) DL560 Server User Manual


 
Availability
Standard Advanced ECC functionality detects and corrects single bit and specific multi-bit
memory errors (4bit and 8bit) while using industry standard registered DIMMS. Functionality
is embedded in the chipset design.
HP Advanced Memory Protection Technology – delivers unsurpassed memory protection
and server availability:
Online Spare Memory:
Offers a higher level of memory protection than Advanced ECC alone. If the number
of single-bit correctable errors on a bank exceeds the pre-defined error threshold, that
bank will fail over to the online spare bank without intervention or server interruption.
The failed memory can then be replaced at the user's convenience during a
scheduled maintenance window.
NOTE:
All HP Advanced Memory Protection modes are user configurable through the ROM-
Based Setup Utility (RBSU) and viewable through Insight Manager 7 and the Integrated
Management Log (IML.).
Smart Array 5i Plus Controller with standard Battery Backed Write Cache (BBWC) Enabler
provides transportable data protection and increases overall controller performance. Up to
64MB Battery Backed Write Cache protection available on 2P HP ProLiant DL560 models
(BBWC Enabler is optional on 1P model).
Redundant Cooling Zones across major server subsystems (Memory, I/O, CPU) provide
7x24 cooling. Each zone is independent of each other and is able to support N+1
redundancy, as indicated below.
This zone configuration enables the server to withstand up to three fan failures, provided that they
are not within the same zone. Each fan is hot plug redundant and individually removable.
Up to two Hot Plug Ultra3 Drive Bays
Simplex SCSI Backplane
Dual Hot Plug Redundant Power Supplies (standard on 2P Models, one ships standard on
1P Models)
Serviceability
Innovative Diagnostic Lighting
LED display on front panel indicates power, internal health, external health, Unit ID light.
Tool-less, virtually cable-less interior design
Tool-less access to interior of server
Lift up hood access to processors and primary fans
Ejectable, slimline media drives (and CD-ROM standard with support for optional
DVD-ROM drives) is removable without the use of tools. Also has fixed floppy drive.
PCI Card Guides locks full length PCI cards in place during transit
Up to ten individually removable fans connect without cables to the system board
Processor/VRM Retention mechanism securely locks both processor and VRM into
their respective sockets
Tool-less removal of system board
Quick Deploy Rails
Tool-less design "snap in" rail
QuickSpecs
HP ProLiant DL560
Standard Features
DA - 11595 Worldwide QuickSpecs — Version 46 — 12.16.2005
Page 7