HP (Hewlett-Packard) DL580 Personal Computer User Manual


 
QuickSpecs
hp ProLiant DL580 Generation 2 (G2)
DA-11372 World Wide — Version 25 — March 20, 2003 6
Standard Features
Serviceability
Innovative Diagnostic Lighting
QuickFind Diagnostic Display – precisely depicts all major subsystems of the server (PCI-X I/O, Memory,
CPU, Redundant Cooling, Interlock, Thermtrip) and gives instant visual indication of fault status. Located on
top front of server.
LED display on front panel indicates power, internal health, external health, Unit ID light.
LED display on Memory board indicates Memory status, health, and protection mode.
Tool-less, virtually cable-less interior design
Tool-less access to interior of server
Two ejectable, slim line media drives (diskette and CD-ROM standard with support for optional DVD-
ROM drives) are removable without the use of tools
Front access power supplies
Spring-loaded memory board release latches prevent unseating incidents
PCI Card Guides locks full length PCI cards in place during transit
SCSI Duplex/Simplex Drive Cage connects directly to system board – no cables.
NOTE: Confi
g
ure
y
our SCSI Duplex/Simplex Drive Ca
g
e b
y
means of simple switch
(
duplex to simplex
)
located on the cage itself. System ships standard in Duplex mode.
Seven individually removable fans connect without cables to the system board
Processor/VRM Retention Cage securely locks both processor and VRM into their respective sockets
Tool-less removal of system board
Quick Deploy Rails
Tool-less design “snap in” rail
Security
Power-on password
Keyboard password
Diskette drive control
Diskette boot control
Network Server Mode
Security Provision
Serial interface control
Administrator’s password
Disk configuration lock
Hot plug access security
Removable Diskette drive
Removable CD-ROM drive
Power Supply
800-Watt (low line or high line) Hot Plug Power Supply
NOTE: One 800-Watt Hot Plug Power Supply ships standard with 1P Models (optional Redundant Hot Plug
Power Supply Option Kit).
NOTE: Two 800-Watt Hot Plug Power Supplies ship standard with 2P Models.
System Fans
Standard 7 Hot plug, redundant fans (individually removable)
Maximum 7 Hot plug, redundant fans (individually removable)
Redundant Cooling Zones across major server subsystems (Memory, I/O, CPU) provide 7x24 cooling. Each
zone is independent of each other and is able to support n+1 redundancy, as indicated below:
- PCI-X expansion zone is 1+1 redundant (fans 1 and 2)
- Memory zone is 1+1 redundant (fans 3 and 4)
- CPU zone is 2+1 redundant (fans 5, 6, and 7)
This zone configuration enables the server to withstand up to three fan failures, provided that they are not
within the same zone. Each fan is hot plug redundant and individually removable.
Required Cabling
For required cabling information, refer to the HP Web site at
http://www.compaq.com/products/servers/proliantDL580/.