HP (Hewlett-Packard) dx2708 MT Personal Computer User Manual


 
Service Reference Guide 431672-001 B–1
B
Power Cord Set Requirements
The voltage select switch feature on the computer permits it to operate from any line voltage
between 100-127 or 220-240 volts AC (230V-China only). (a) When dx2700 MT/dx2708 MT/
dx2700 SFF are assembled and shipped only for China, or Korea, or Australia/New Zealand
Market, there aren't power switch selector with installed power supply. (b) When dx2700 MT and
dx2700 SFF are intended to be assembled and sold for Non-China region (exclusive above
countries mentioned on (a)), there are power switch selector with installed power supply.
The power cord set received with the computer meets the requirements for use in the country
where you purchased the equipment.
Power cord sets for use in other countries must meet the requirements of the country where you
use the computer. For more information on power cord set requirements, contact your authorized
HP dealer, reseller, or service provider.
General Requirements
The requirements listed below are applicable to all countries:
1. The length of the power cord set must be at least 1.8 m (6.00 feet) and a maximum of 3.0 m
(9.75 feet.)
2. All power cord sets must be approved by an acceptable accredited agency responsible for
evaluation in the country where the power cord set will be used.
3. The power cord set must have a minimum current capacity of 10A and a nominal voltage
rating of 115 to 230 volts AC, as required by each country’s power system.
4. The appliance coupler must meet the mechanical configuration of an EN 60 320/IEC 320
Standard Sheet C13 connector, for mating with appliance inlet on the Switch Box.