HP (Hewlett-Packard) E1367A Computer Hardware User Manual


 
SYSTem
The SYSTem subsystem returns error numbers/messages in the error queue
of a switchbox, and returns module types and descriptions in a switchbox.
Subsystem Syntax SYSTem
:ERRor?
:CDEScription? <
number>
:CTYPe?
<
number
>
:CPON
<
number
> |
ALL
:ERRor? SYSTem:ERRor? returns the error numbers/messages in the error queue of
a switchbox. See Appendix C for error message information.
Comments Error Numbers/Messages in the Error Queue: Each error
generated by a switchbox stores an error number and corresponding
error message in the error queue. The error number is always
negative and the error message can be up to 255 characters long.
Clearing the Error Queue: An error number/message is removed
from the queue each time the
SYSTem:ERRor? command is sent.
The errors are cleared first-in, first-out. When the queue is empty,
each following
SYSTem:ERRor? command returns 0, “No error”.
To clear all error numbers/messages in the queue, execute
*CLS.
Maximum Error Numbers/Messages in the Error Queue: The
queue holds a maximum of 30 error numbers/messages for each
switchbox. If it overflows, the last error in the queue is replaced by
-350, “Too many errors”. The least recent error numbers/messages
remain in the queue and the most recent are discarded.
Example Reading the Error Queue
SYST:ERR? ! Query the error queue
:CDEScription? SYSTem:CDEScription? <number> returns the description of a selected
module (card) in a switchbox.
Parameters
Parameter Name Parameter Type Range of Values
<number> numeric 1-99
Comments RF Multiplexers Module Description:
The
SYST:CDESciption? <number> command returns: “50 Ohm RF
Mux
” for the HP E1366A or “75 Ohm RF Mux” for the HP E1367A.
Example Reading the Description of a Card #1 Module
SYST:CDES? 1 ! Return the description
:CTYPe? SYSTem:CTYPe? <number> returns the module (card) type of a selected
module in a switchbox.
54 HP E1366A/E1367A RF Multiplexers Command Reference Chapter 5