HP (Hewlett-Packard) JD311B Switch User Manual


 
To view Boot ROM accessibility status, use the display startup command. For more information about the
display startup command, see the Fundamentals Command Reference.
Follow the step below to disable Boot ROM access:
To do… Use the command… Remarks
Disable Boot ROM access
undo startup bootrom-access
enable
Required
By default, Boot ROM access is
enabled.
Available in user view.
Configuring the detection timer
Some protocols might shut down ports under specific circumstances. For example, MSTP shuts down a
BPDU guard enabled port when the port receives a BPDU. Then, the device starts the detection timer. If
the port is still down when the detection timer expires, the port quits the shutdown status and resume its
actual physical status.
Follow these steps to configure the detection timer:
To do… Use the command… Remarks
Enter system view system-view
Configure the detection timer shutdown-interval time
Optional
The detection interval is 30
seconds by default.
Configuring temperature alarm thresholds
(available only on the A3100 v2 EI)
You can set the temperature alarm thresholds to monitor the temperature of a device.
The temperature alarm thresholds include lower temperature limit, warning temperature threshold, and
temperature alarming threshold.
When the device temperature drops below the lower limit or reaches the warning threshold, the device
logs the event and outputs a log message and a trap.
When the device temperature reaches the alarming threshold, the device constantly outputs log and tap
messages to the configuration terminal and lights the temperature alarm LED on the device panel.
Follow these steps to configure temperature alarm thresholds:
To do… Use the command… Remarks
Enter system view system-view
135