Hot Plug SATA
Quantity
Supported
Position
Supported
Controller
750GB 1.5G SATA 7.2K
500GB 1.5G SATA 7.2K
250GB 1.5G SATA 7.2K
160GB 1.5G SATA 7.2K
80GB 1.5G SATA 7.2K
Up to 4
1-4
Embedded SATA with integrated SATA RAID 0,1
HP SC40Ge SAS HBA with RAID
HP 8 Internal Port SAS HBA with RAID
HP Smart Array E200/128 BBWC Controller
HP Smart Array E500/256 MB Controller
HP Smart Array P400/256 MB Controller
HP Smart Array P400/512 MB BBWC Controller
HP Smart Array P800/512 BBWC Controller
NOTE:
Hot plug capability and drive LED status support requires installation of one of the controllers or HBAs listed above.
External Storage
Quantity
Supported
Position
Supported
Controller
Modular Smart Array 60
Enclosure
Up to 8
External
HP Smart Array P800/512 BBWC Controller
HP Smart Array E500/256 MB Controller
Modular Smart Array 70
Enclosure
Up to 4
External
HP Smart Array P800/512 BBWC Controller
HP Smart Array E500/256 MB Controller
Tape Drives, Tape Autoloaders, Tape Libraries & D2D Backup
NOTE:
For an up-to-date listing of the latest O/S Support details for each of the Tape Drives listed below, please see the
following:
http://h18000.www1.hp.com/products/quickspecs/division/10233.html
(Worldwide)
NOTE:
For an up-to-date listing of the latest O/S Support details for each of the Tape Autoloaders and Tape Libraries listed
below, please see the following:
http://h18000.www1.hp.com/products/quickspecs/division/10809.html
(Worldwide)
NOTE:
For complete listing of tape drive offerings see
http://www.hp.com/products1/storage/compatibility/tapebackup/ISS/index.html
NOTE:
SAS Tape Drives: Connecting hard drive cage and SAS tape to the same SAS Controller using split cable (supplied
with tape drive) deactivates 1 of the hard drive bays. Actual hard drive bay deactivated depends on where split cable plugs
into SAS drive connector. Example: 3x SAS cable connector plugged into SAS drive connector (5-8) on the back of the hard
drive cage would mean drive bay 8 is deactivated.
Position
Supported
Controller
Controller/HBA
Option Kit Part
Number
HP StorageWorks SCSI
Tape Drives, Internal
LTO-1 Ultrium 232
LTO-2 Ultrium 448
LTO-2 Ultrium 460
LTO-3 Ultrium 920
LTO-3 Ultrium 960
LTO-4 Ultrium 1840
DAT 40
DAT 72
DAT 160
DLT VS160
SDLT 600
Internal
64-Bit/133-MHz Single Channel Ultra320 SCSI HBA G2
374654-B21
QuickSpecs
HP ProLiant ML310 Generation 5
Storage
DA - 12858 Worldwide QuickSpecs — Version 15 — 4/15/2008
Page 26