Hitachi CP-S830W/E Projector User Manual


 
29
ENGLISH
Install the lamp cover and fix it using screws.
· To prevent burn, install the lamp cover and secure it using screws.
· When the lamp cover is out of place, the power does not turn on. Before you turn
on the power, make sure to attach the lamp cover and fix it with the scrcws.
5
Lamp
(continued)
Please carry out the following operation within 10 minutes from power on, if you replaced the lamp after
2,000 hours.
2. Reset the lamp time
3
1
2
RIGHT
RESET
STANDBY/ON
MENU
TIMER
BLANK
VOL
3
1, 2
RESET
MENU
MUTE INPUT
LAMP TEMP
ON
STANDBY/ON
1) Press the RESET button on projector for 3 seconds or remote control TIMER
button for 3 seconds and display the total lamp used time.
· When accumulated operation time of the lamp reaches 1700 hours, the
following display will appear at the bottom of the screen.
2) Press the RESET button on projector or remote control MENU ON button
during displaying the lamp used time.
3) Select the Ò0Ó on the screen using the MENU ( ) button or MENU STICK
SWITCH.
LAMP 1700 0 CANCEL
LAMP 1700 h
®Ÿ
Whenever the lamp is replaced, reset the total operation time of the lamp.
Do not reset if the lamp has not been replaced.
On-screen display
The following messages are displayed on the screen.
Message table
*1 This message are not displayed after 3 minutes.
But this message are displayed when you turn on the power again.
MESSAGE Action
CHANGE THE LAMP
"AFTER REPLACING LAMP,
RESET THE LAMP TIMER."
Accumulated operation of lamp has exceeded 1,700 hours. It is recommended
to replace lamp. Replace with new lamp. If accumulated operation reaches
2,000 hours, lamp will automatically turn off. *1
CHANGE THE LAMP
"AFTER REPLACING LAMP,
RESET THE LAMP TIMER."
THE POWER WILL TURN
OFF AFTER 20 Hr.
Lamp has 1,979 hours on it.
Call a maintenance person. *1
Time is 20 ~ 0. (count down.)
Blinking of
"CHANGE THE LAMP"
When the lamp has 2,000 hours or more on it, the message will blink, and the
power will turns off after 10 minutes.
NO INPUT IS DETECTED Signal is hot input. (See page 18, 19)
SYNC IS OUT OF RANGE
The horizontal frequency of the input signal exceeds the range of the projector,
it cannot be displayed. (See page 19, 20)
CHECK THE AIR FLOW Clean the air filter of remove the blocking ventilation holes. (See page 27)