Hitachi CP-X3011N Projector User Manual


 
57
OPTION menu
Item Description
SERVICE
(continued)
COMMUNICATION
(continued)
COMMUNICATION TYPE
Select the communication type for transmission via
the CONTROL port.
NETWORK BRIDGE
OFF
NETWORK BRIDGE:
Select this type, if it is required
to control an external device as a network terminal,
via this projector from the computer.
The CONTROL port doesn't accept RS-232C
commands (
Network Bridge Function in the
User’s Manual - Network Guide
)
OFF: Select this mode to receive RS-232C
commands using the CONTROL port.
OFF is selected as the default setting.
• When you select the NETWORK BRIDGE, check
the item, TRANSMISSTION METHOD
(
below)
.
SERIAL SETTINGS
Select the serial communication condition for the
CONTROL port.
BAUD RATE
4800bps
9600bps
19200bps
38400bps
PARITY
NONE
ODD
EVEN
The BAUD RATE is fixed to 19200bps and PARITY
is fixed NONE when the COMMUNICATION TYPE
is set to OFF
(
above)
.
TRANSMISSION METHOD
Select the transmission method for communication by
the NETWORK BRIDGE from the CONTROL port.
HALF-DUPLEX
FULL-DUPLEX
HALF-DUPLEX: This method lets the projector
make two way communication, but only one
direction, either transmitting or receiving data, is
allowed at a time.
FULL-DUPLEX: This method lets the projector
make two way communication, transmitting and
receiving data at the same time.
• HALF-DUPLEX is selected as the default setting.
• If you select HALF-DUPLEX, check the setting of
the item RESPONSE LIMIT TIME
(
58)
.
(continued on next page)
Downloaded from www.Manualslib.com manuals search engine