Hitachi ED-X52 Projector User Manual


 
14
Please check and clean the air fi lter periodically. When the indicators or a message
prompts you to clean the air fi lter, comply with it as soon as possible. The air fi lter has two
kinds of fi lters inside. Replace the fi lters when they are damaged or too soiled. To prepare
the new fi lters, make contact with your dealer and tell the following type number.
Type number : UX36761 (Filter set)
When you replace the lamp, please replace the air fi lter. An air
fi lter of specifi ed type will come together with a replacement
lamp for this projector.
1.
Turn the projector off, and unplug the power cord. Allow the
projector to suffi ciently cool down.
2.
Use a vacuum cleaner on and around the fi lter cover.
3.
Pick and pull up the fi lter cover knobs to take it off.
4.
Use a vacuum cleaner for the fi lter vent of the projector.
5.
Take the fi ne meshed fi lter out while holding the fi ltercover.
It is recommended to leave the coarse meshedfi lter in the
fi lter cover as it is.
6.
Use a vacuum cleaner on both sides of the fi ne meshed
fi lter while holding it so it will not be sucked in. Use a
vacuum cleaner for the inside of the fi lter cover to clean
up the coarse meshed fi lter. If the fi lters are damaged or
heavily soiled, replace them with new ones.
7.
Put the fi ne meshed fi lter on the coarse meshed one,
turning its stitched side up.
8.
Put the fi lter unit back into the projector.
9.
Turn the projector on and reset the fi lter time using the
FILTER TIME item in the EASY MENU.
(1) Press the MENU button to display a menu.
(2) Point at the FILTER TIME using the / button, then
press the button. A dialog will appear.
(3) Press the button to select “OK” on the dialog. It
performs resetting the fi lter time.
Cleaning and replacing the air fi lter
WARNING Before taking care of the air fi lter, make sure the power cable
is not plugged in, then allow the projector to cool suffi ciently.
Use only the air fi lter of the specifi ed type. Do not use the projector without the
air fi lter or the fi lter cover. It could result in a fi re or malfunction to the projector
.
Clean the air fi lter periodically. If the air fi lter becomes clogged by dust or the like,
internal temperatures rise and could cause a fi re, a burn or malfunction to the projector.
NOTE • Please reset the fi lter time only when you have cleaned or replaced
the air fi lter, for a suitable indication about the air fi lter.
• The projector may display the message such as “CHECK THE AIR FLOW” or
turn off the projector, to prevent the internal heat level rising.
2
Filter (fi ne meshed)
Filter (coarse meshed)
7
Stitched
side
4
Intake vent
Filter cover
Filter cover knobs
3