Honeywell 1250G Scanner User Manual


 
3 - 14
ger scanning. Scan the bar code below, then use the Programming Chart
to read the alphanumeric combination that represents that ASCII character.
Scan Save to finish.
End Character Activation After Good Read
After a bar code is successfully detected and read from the scanner, the
laser can be programmed either to remain on and scanning, or to turn off.
When End Character Activation After Good Read is enabled, the laser
turns off and stops scanning after a good read. If you scan Do Not End
Character Activation After Good Read, the laser remains on after a good
read.
Default = End Character Activation After Good Read.
Character Activation Laser Timeout
You can set a timeout for the length of time the laser remains on and
attempting to decode bar codes when using Character Activation Mode.
Set the length (in milliseconds) for a timeout by scanning the bar code
below, then setting the timeout (from 1-65535 milliseconds) by scanning
digits from the Programming Chart, then scanning Save.
Default = 5000
ms.
Activation Character
* End Character Activation After
Good Read
Do Not End Character Activation
After Good Read
Character Activation Laser
Timeout