Honeywell 3800g Scanner User Manual


 
3 - 4 3800g/3800gHD/3800gPDF User’s Guide
ger command. After scanning the Read Time-Out bar code, set the time-out
duration (from 0-300,000 milliseconds) by scanning digits from the inside back
cover, then scanning Save.
Default = 30,000.
Automatic Trigger
The imager scans continuously using internal LEDs to detect bar codes.
Presentation Mode
Presentation Mode uses ambient light to detect bar codes. The LEDs are off for
ambient conditions until a change occurs in the imager’s field of view. Then the
LEDS turn on automatically to read the code. If the light level in the room is not
high enough, Presentation Mode may not work properly.
Continuous Illumination Mode
If you have several bar codes that are close together, you may wish to have a
continuous aiming beam on in order to properly aim the imager at one bar code.
Scan the Continuous Illumination On bar code to program the imager for this
capability. Once you have the aiming beam over the correct bar code, pull the
trigger to read the code. Scan the Continuous Illumination Off bar code to
turn off this feature.
Hands Free Time-Out
The Automatic Trigger and Presentation Modes are referred to as “hands free”
modes. If the imager’s trigger is pulled when using a hands free mode, the
imager changes to manual trigger mode. You can set the time the imager
should remain in manual trigger mode by setting the Hands Free Time-Out.
Once the time-out value is reached, (if there have been no further trigger pulls)
the imager reverts to the original hands free mode.
Read Time-Out
Automatic Trigger
Presentation Mode
Continuous Illumination Mode On
* Continuous Illumination Mode Off