Honeywell 800-08115 Network Card User Manual


 
SCREW
(3)
SIM
CARD
5000-100-151-V1
ROTATED
180
CONNECTOR
BOARD
CONNECTOR
BOARD
RECEPTACLE
GSMVLP5
LYNX TOUCH
LOCKING TABS
Figure 2. Installing the GSMVLP5 in the LYNX Touch
Installing the ILP5 in the LYNX Touch Series Control
Ensure that the connector board and cable are securely installed in the ILP5 before installing the module
in
the LYNX Touch.
1. Release the LYNX Touch front case from the back case by depressing the two locking tabs at the top of the
unit with the blade of a medium size screwdriver (Refer to Figure 3).
2. Using a wire cutter or knife cut the plastic tabs that secure the ILP5 spacer to the back case of the LYNX
Touch (Refer to Figure 3).
3. Remove the ILP5 receptacle knockout from the left side of the LYNX Touch back case (Refer to Figure 3).
4. Install the ILP5 into the LYNX Touch control front case. Ensure that the connector board is properly seated
into the receptacle on the control (Refer to Figure 3).
5. Secure the ILP5 with the three provided screws (Refer to Figure 3).
6. Insert the ILP5 receptacle and spacer into the slot on the back case (Refer to Figure 3).
7. Secure the communications cable to the tie wrap point on the ILP5 with the provided tie wrap (Refer to
Figure 3).
8. Enable the ILP5 and configure alarm reporting and module supervision and register the device. Refer to the
“Program the Radio” and “Diagnostics” sections in the LYNX Touch Series Installation and Setup Guide
(P/N 800-06834 or higher).
For Documentation and Online Support: http://www.security.honeywell.com/hsc/resources/MyWebTech