Honeywell ST6300 Network Router User Manual


 
ELECTRONIC PROGRAMMER ST6300
Installation
ST6300 can be either surface or flush
switch box mounted, for both of which
fixing screws are supplied. The wiring
sub-base has holes to suit single
switch boxes and breakouts for
surface wiring and mini-trunking.
When wiring is completed the plug-in
module is fitted onto the sub-base
and secured by tightening the
retaining screws.
Ordering Specification
ST6300A1007
Electronic programmer having two
ON/OFF periods with separate outputs
for heating and hot water circuits.
Wiring
Specification
Switch Type : Single Pole Double Throw (SPDT)
Switch Rating : 3(3)A
Timing Accuracy : ±1 min/month
Timing Resolution : Time of Day 1 minute
: Programme Times 10 minutes
Ambient Operating
Temperature : 0-50˚C
Power Reserve : Minimum 4 days
Weight : 330g approx (including wall plate)
Earthing : Double Insulated
Battery Back-Up : Integral battery with built-in charging circuit
Standards : Complies with BS EN60730-2-7
EC Directive : Conforms to 89/336/EEC & 73/23/EEC
Dimensions (mm)
A
B
C
D
ABCD
145 95 45 120
ST 6300
Clock
OFF
OFF
ON
ON
CH ON
CH OFF
HW ON
TIMED OUTPUTS
HW OFF
NL1234
3 AMPS MAX
N
L
230V~
50...60Hz