Honeywell UDC 6300 Network Card User Manual


 
8
Industrial Automation and Control
Honeywell Inc.
http://www.iac.honeywell.com
U.S.A.: Honeywell Industrial Automation and Control, 16404 North Black Canyon Hwy., Phoenix, AZ 85053
Canada: The Honeywell Centre, 155 Gordon Baker Rd., North York, Ontario M2H 3N7
Latin America: Honeywell Inc., 480 Sawgrass Corporate Parkway, Suite 200, Sunrise, Florida 33325
Japan: Industrial Operations Tokyo, 4-28-1 Nishi-Rokugo Ohtu-ku, Tokyo 144, Japan
Asia: Honeywell Asia Pacific Inc., Room 3213-3225, Sun Hung Kai Centre, No. 30 Harbour Road, Wanchai, Hong Kong
Pacific Division: Honeywell Pty Ltd., 5 Thomas Holt Drive, North Ryde NSW Australia 2113
Northern Europe and Southern Africa: Honeywell Ltd., Honeywell House, Arlington Business Park, Bracknell, RG 12 1EB, U.K.
Central Europe: Honeywell A.G., Kaiserleistraße 39, 63067 Offenbach, Germany
Western and Southern Europe: Honeywell S.A., Avenue de Schiphol 3, 1140 Brussels, Belgium
Eastern Europe: Honeywell Praha, s.r.o., Budejovicka 1, 140 00 Prague 4, Czech Republic
Middle East: Honeywell Middle East Ltd., Khalifa Street, Sheikh Faisal Building, Abu Dhabi, U.A.E.
©Honeywell Inc. Printed in U.S.A.
Recycled Paper
4 Analog Inputs
– 1 to 5 Vdc, 4-20mA or 10 to 50 mA
– Isolated from all other inputs and outputs
Universal Input — isolated
– Thermocouple – Millivolts or Volts
– RTD – Pulse
1 or 2 Current Outputs
– 4-20mA dc
– Isolated
4 Universal Digital Inputs /Outputs
– Open-collector outputs or digital inputs
– Externally powered
2 Digital Inputs
– User configurable
– Isolated
Math Functions
– summer – input/output
– weighted average characterization
– multiplier/divider – logic
– hi/lo select – totalization
Serial Communications Link
– RS485 TDC 3000 Integration – DMCS
– RS422/485 — 15 drops
Transmitter Power
24Vdc
±
2V
50mA dc for one or two transmitters
Accuracy
– ±0.01% of span for linear inputs
– ±0.02% of span typical for T/C and RTD inputs
Temperature Stability
±0.005% per F° typical
Pulse Input
Range: 1Hz to 25K Hz
Power Consumption
– 20 VA maximum
Splashproof faceplate
Power Requirements
– 24Vdc, 120 Vac or 240 Vac
CE Mark Compliant
– Full conformity with CE directives
51-51-58-18 (7.5M) 10/98
Condensed Specifications (some features are optional)
For complete product specifications please request
document 51-52-03-13.
Specifications are subject to change without notice.
™ACCUTUNE is a U.S. trademark of Honeywell, Inc.
*All other brand and product names are trademarks of their respective owners.
144
5.67
72
2.83
138
5.43
+1.0
-0
+0.039
-0
+0.7
-0
+0.027
-0
68
2.68
panel cutout
(DIN
Standard)
Dimensions:
millimeters
inches
233
9.19
max
33
1.22
max
25
1.00
Max. Panel
thickness
NOTES:
1. Drawing is not to scale
2. No minimum horizontal
spacing is defined.
3. Controller may be
mounted at any angle
or tilt.
Rear Terminal Cover