Hoshizaki KM-2400SRH3 Server User Manual


 
20
6) Bin Control
CAUTION
When the ambient temperature is below 45°F, the Bin Control Thermostat
operates to stop the icemaker even if the Ice Storage Bin is empty. When
the Thermostat is set in the prohibited range, the icemaker operates con-
tinuously even if the Ice Storage Bin is filled with ice. Setting in the prohib-
ited range might cause severe damage to the icemaker resulting in failure.
No adjustment is required under normal use, as the Bin Control is factory-adjusted.
Adjust it, if necessary, so that the icemaker stops automatically within 10 seconds after
ice contacts the Bin Control Thermostat Bulb.
[e] CHECKING THE CONTROLLER BOARD
1) Visually check the sequence with the icemaker operating.
2) Visually check the Controller Board by using the following procedures.
(i) Adjust the Defrost Timer to minimum position.
Disconnect the Thermistor from the Controller Board.
Connect a 1.5 k - 3.5 k resistor to the Connector K3 (pins #1 and #2), and energize
the unit.
5) Freeze Timer
CAUTION
Adjust to proper specification, or the unit may not operate correctly.
Two new dip switches numbered 9 and 10 have been added to the improved “E” board to
better prevent possible freeze ups. These settings come factory set to the default setting
of 50 min. (OFF, ON). Check the adjustment chart published in the Tech Specs for proper
settings.
SETTING TIME
Dip Switch Dip Switch
No. 9 No. 10
OFF OFF 60 min.
ON OFF 70 min.
OFF ON 50 min.
ON ON 60 min.