Hubbell 100E Switch User Manual


 
Static In-Line Timer
Solid state, in-line timing unit for AC or DC contactor and relay control circuits where a
timed “ON” delay is required. Typical application is on crane and mill drives. The tim-
ing range is field adjustable by integral potentiometer and ranges from 0.08 seconds to
16.0 seconds, depending on model.
Standard features include:
• Totally encapsulated, solid state design.
• Shock a vibration resistant.
• Wide range ambient temperature operation.
Electronic Frequency Relay
Master/slave system designed to be used with wound rotor motor controls. Master
unit, which can be used as a stand-alone relay, is a complete frequency relay provid-
ing one point of frequency detection. The slave unit must be used with the master
unit and provides additional point of frequency detection. Up to five slave units can
be used with each master.
Standard features include:
• Green “Relay-on” and red “Relay Picked-up” indicators.
• 5.5–218 hz response range.
• Single frequency adjustment set point for each device.
• Hand held calibration module to monitor, calibrate or troubleshoot the system.
EUCLID
TM
AC & DC Controller Components
Arc Suppressor
Designed to reduce contact arcing in DC control circuits with operating voltages
between 24 and 275 volts DC. When permanently connected in parallel with the oper-
ating coil, the arc suppressor may eliminate the use of an interposing relay.
Standard features include:
• Totally encapsulated, electronic design.
• Shock and vibration resistant.
• Operating voltage 24 to 275 volts DC.
• Operating temperature range from -40º to 65ºC.
Electronic Overload Relay
Performs both the inverse time and instantaneous trip functions normally
performed by two separate electro-mechanical overload relays. It receives
the current signals from an optional ammeter shunt and may be used with
any dc motor that requires overload current protection.
Standard features include:
• Automatic reset. Manual reset of trip indicators.
• Green “Overload-on” and yellow “Overload-Condition” indicators.
• Negative or positive shunt applications.
• Mill-duty design.
• Double break contacts.
• Latched red “Overload-Trip” indicators.
Lifting Magnet Controls
Varistor or resistor type, automatic discharge or manual, EUCLID has them.
Discharge resistor and varistor types provide safe discharge path for stored
energy. EUCLID
TM
magnet controls are kind to your lifting magnet. They all
feature:
• Suited for many uses from light scrap to heavy billets or plates.
• Fast and clean release of full load load.
• Accurate release of partial load.
• Precise control of dribbling.
• Front wired and front accessible components for quick
installation and service.
Model 4291–Varistor type. Automatic discharge
• 50 to 350 Amps cold magnet current.
•Mill duty, Long contact life, Minimum maintenance.
Model 4292–Yardmaster. Varistor type. Automatic discharge
• 5 to 100 Amps cold magnet current.
• Heavy-duty time proven components arranged to provide optimum
control of your lifting magnets.
• Mechanically interlocked “Lift” and “Drop” NEMA rated
mill duty contactors.
Model 4295–Resistor type. Automatic discharge
• 13 to 175 Amps cold magnet current.
• Mechanically rugged high thermal capacity discharge resistor .
• Permanently connected discharge path completely independent
of the line.
• Mechanically interlocked “Lift” and “Drop” contactors.
Model 4296–Resistor type. Manual discharge
• 13 to 130 Amps cold magnet current.
• Heavy-duty time proven components. Minimum maintenance.
• Mechanically interlocked “Lift” and “Drop” contactors.
Lifting Magnet Power Supplies
Diode rectifier designed and rated for the demanding requirements where short circuits on
the DC bus are common or a problem.
• High capacity discharge resistor.
• Supplied in a NEMA type 3R wall mounting enclosure.
Lifting Magnet Disconnect Switch
Fused safety disconnect switch designed to safely allow the operator to disconnect a highly
inductive lifting magnet while the magnet is still energized. Standard safety switches are not
designed to disconnect an energized magnet.
• High capacity discharge resistor.
• Supplied in a NEMA type 3R wall mounting enclosure
EUCLID
TM
Magnet Controls and Disconnect Switches
6 3
Type 5330
Frequency Relay
Type 5350 Static In-Line Timer
Type 5360 Arc Suppressor
Model 4292 Yardmaster
Lifting Magnet Control