Hubbell 4015 Power Supply User Manual


 
Hubbell Industrial Controls, Inc.
A subsidiary of Hubbell Incorporated
4301 Cheyenne Dr., Archdale, NC. 27262
Telephone (336) 434-2800 • FAX (336) 434-2803
http://www.hubbell-icd.com
Sales@hubbell-icd.com
ELEMENTARY DIAGRAM FOR HOIST CONTROL
TYPICAL CRANE PERFORMANCE CURVES
TYPE 4015 DC DYNAMIC LOWERING CONTROL
(RECTIFIED AC POWER) 300 VOLT DC
D
IMENSION DATA
SINGLE MOTOR CONTROL WITH PROTECTION
APPROXIMATE DIMENSIONS AND WEIGHTS
(DO NOT USE FOR CONSTRUCTION PURPOSES)
ENCLOSED CONTROL PANEL
Max HP
Crane Rating
230 vdc
HWD
Net
Weight
(lbs.)
35 72 45 16 900
55 72 45 16 900
110 80 45 18 1100
225 85 94 24 2000
330 85 94 24 2100
Panel modifications may change controller dimensions.
Door swing is limited to 20" or less.
ENCLOSED RECTIFIER PANEL
Max HP
Crane Rating
230 vdc
HWD
Net
Weight
(lbs.)
35 60 24 22 500
65 60 24 22 500
100 60 24 22 500
135 60 40 22 800
200 60 40 22 800
330 72 50 22 1200
Door swing is limited to 20" or less.
TRANSFORMER
Max HP
Crane Rating
230 vdc
HWD
Net
Weight
(lbs.)
19 26 26 20 300
35 28 27 20 400
45 30 29 20 500
65 36 35 24 600
100 39 38 28 800
135 48 47 30 1100
200 51 48 30 1300
265 53 50 35 1800
NOTE: Transformer for 100 HP and above are floor
mounted only.
APPROXIMATE NUMBER OF SEPARATELY MOUNTED STANDARD "Z" LENGTH RESISTOR
FRAMES (26.5" LONG)
Horsepower 10 13½ 19 26 33 45 65 100 135 200 265
NEMA Class 162 DL 5 5 6 8 10 12 17 21 30 43 53
NEMA Class 172 DL 7 7 9 11 14 17 24 30 42 60 74
X = DENOTES CONTACTS CLOSED
CONTACTORS 1A AND L, K AND H, H AND J
ARE MECHANICALLY INTERLOCKED
CURVES ARE BASED ON AN ASSUMED
HOIST DRIVE EFFICIENCY OF 80%