IBM 149H Laptop User Manual


 
Error
Code
Message FRU/Action in Sequence
050 IDE Drive 0
Error
Hard disk connection
board
Hard disk drive
Planar board
054 IDE Drive(s)
Disabled
Hard disk drive cable
Hard disk drive
056 IDE Drive 0
Auto Detection
Failed
Hard disk connection
board
Hard disk drive
Planar board
070 Real Time
Clock Error
Reset time in the
"Basic System Set-
tings" menu of the
BIOS Utility.
Backup battery (RTC
battery)
Planar board
071 CMOS Battery
Bad
Enter BIOS Utility and
execute "Load Setup
Default Settings".
Backup battery (RTC
battery)
Planar board
072 CMOS
Checksum
Error
Enter BIOS Utility and
execute "Load Setup
Default Settings"; then
reboot the system.
Backup battery (RTC
battery)
Planar board
006 Equipment
Configuration
Error
Ensure the equipment
(diskette drive, hard
disk drive, keyboard,
external mouse, etc.) is
connected properly
and is correctly set in
the BIOS Utility.
Hard disk connection
board
Hard disk drive
Planar board
System Operation (Runtime)
103 Press <Esc>
to turn off NMI
or other key to
reboot
Enter BIOS Utility and
execute "Load Setup
Default Settings"; then
reboot the system.
Remove the non-
factory-installed
adapter card and
reboot the system.
18 ThinkPad i Series 1400