Diagnostic Error Code FRU/Action
000-038-XXXBIOS Extension failure
1. Flash the system
2. Adapter card
3. System board
000-039-XXXBIOS DMI data error
1. Flash the system
2. System board
000-195-XXXBIOS Test aborted by user
1. Information
2. Re-start the test, if necessary
000-196-XXXBIOS test halt, error threshold
exceeded
1. Press F3 to review the log file
2. Re-start the test to reset the log file
000-197-XXXBIOS test warning
1. Make sure the component that is called out is
connected and/or enabled
2. Re-run test
3. Component that is called out in warning statement
4. Component under test
000-198-XXXBIOS test aborted
1. If a component is called out, make sure it is
connected and/or enabled
2. Flash the system and re-test
3. Go to the Undetermined problems section
000-199-XXXBIOS test failed, cause unknown
1. Go to the Undetermined problems section
2. Flash the system and re-test
3. Replace component under function test
000-250-XXXBIOS APM failure
1. Flash the system
2. System board
000-270-XXXBIOS ACPI failure
1. Flash the system
2. System board
001-000-XXXSystem Test Passed
1. No action
001-00X-XXXSystem Error
1. System board
001-01X-XXXSystem Error
1. System board
001-024-XXXSystem Addressing test failure
1. System board
001-025-XXXSystem Checksum Value error
1. Flash the system
2. System board
001-026-XXXSystem FLASH data error
1. Flash the system
2. System board
2 Hardware Maintenance Manual: IBM NetVista Computer Types 6058, 6059, 6269, 6568, 6569, 6578, 6579, 6648,