IBM 6348 Computer Hardware User Manual


 
POST Error Code FRU/Action
10103, 10110, 101171
1. System Board
2. Data/Fax Modem
3. Riser card
10117
Not listed above
1. Check system speaker
2. Check PSTN cable
3. External DAA
(if installed)
4. Modem
10118
1. Run Diagnostics and verify the correct
operation of the modem slot
2. Modem
10119
1. Diagnostics detected a non-IBM modem
2. Modem
10120
1. Check PSTN Cable
2. External DAA
(if installed)
3. Modem
10132, 10133, 10134,
10135, 10136, 10137,
10138, 10139, 10140,
10141, 10142, 10143,
10144, 10145, 10146,
10147, 10148, 10149,
10150, 10151, 10152
1. Modem
10153
1. Data/Fax Modem
2. System Board
3. Riser card
101XX
Not listed above
1. Modem Adapter/A
2. Data/Fax Modem
3. System Board
4. Riser card
10450, 10451, 10490,
10491, 10492, 10499
Read/write error
1. Run Enhanced Diagnostics
2. Hard Disk Drive
3. System Board
4. Riser card
10452
Seek test error
1. Run Enhanced Diagnostics
10453
Wrong drive type?
Information only
10454
Sector buffer test error
1. Run Enhanced Diagnostics
10455, 10456
Controller error
1. Run Enhanced Diagnostics
10459
Drive diagnostic command error
Information only
Chapter 6. Symptom-to-FRU Index 101