IBM 6568 Personal Computer User Manual


 
Diagnostic Error Code FRU/Action
030-197-XXXSCSI interface test warning
1. Make sure the component that is called out is
connected and/or enabled
2. Re-run test
3. Component that is called out in warning statement
4. Component under test
030-198-XXXSCSI interface test aborted
1. If a component is called out, make sure it is
connected and/or enabled
2. Flash the system and re-test
3. Go to the Undetermined problems section
030-199-XXXSCSI interface test failed, cause
unknown
1. Go to the Undetermined problems section
2. Flash the system and re-test
3. Replace component under function test
035-000-XXXRAID interface Test Passed
1. No action
035-0XX-XXXRAID interface Failure
1. RAID signal cable
2. RAID device
3. RAID adapter card, if installed
4. System board
035-195-XXXRAID interface Test aborted by
user
1. Information
2. Re-start the test, if necessary
035-196-XXXRAID interface test halt, error
threshold exceeded
1. Press F3 to review the log file
2. Re-start the test to reset the log file
035-197-XXXRAID interface test warning
1. Make sure the component that is called out is
connected and/or enabled
2. Re-run test
3. Component that is called out in warning statement
4. Component under test
035-198-XXXRAID interface test aborted
1. If a component is called out, make sure it is
connected and/or enabled
2. Flash the system and re-test
3. Go to the Undetermined problems section
035-199-XXXRAID interface test failed, cause
unknown
1. Go to the Undetermined problems section
2. Flash the system and re-test
3. Replace component under function test
071-000-XXXAudio port Interface Test Passed
1. No action
14 Hardware Maintenance Manual: IBM NetVista Computer Types 6058, 6059, 6269, 6568, 6569, 6578, 6579, 6648,
6649