IBM 8185 Computer Hardware User Manual


 
Diagnostic Error Code FRU/Action
014-198-XXX
Parallel port test aborted
1. If a component is called out, make sure
it is connected and/or enabled
2. Flash the system and re-test
3. Go to “Undetermined problems” on page
109
014-199-XXX
Parallel port test failed, cause unknown
1. Go to “Undetermined problems” on page
109
2. Flash the system and re-test
3. Replace component under function test
014-2XX-XXX
014-3XX-XXX
Parallel port failure
1. External parallel device
2. System board
015-000-XXX
USB port Interface Test Passed
1. No action
015-001-XXX
USB port Presence
1. Remove USB device(s) and re-test
2. System board
015-002-XXX
USB port Timeout
1. Remove USB device(s) and re-test
2. System board
015-015-XXX
USB port External Loopback failure
1. Remove USB device(s) and re-test
2. System board
015-027-XXX
USB port Configuration/Setup error
1. Flash the system
2. System board
015-032-XXX
USB port Device Controller failure
System board
015-034-XXX
USB port buffer
allocation failure
1. Reboot the system
2. Flash the system
3. Run memory test
4. System board
015-035-XXX
USB port Reset condition detected
1. Remove USB device(s) and re-test
2. System board
015-036-XXX
USB port Register error
System board
015-040-XXX
USB port IRQ failure
1. Run setup and check for conflicts
2. Flash the system
3. System board
015-195-XXX
USB port Test aborted by user
1. Information
2. Re-start the test, if necessary
015-196-XXX
USB port test halt, error threshold exceeded
1. Press F3 to review the log file
2. Re-start the test to reset the log file
78 Hardware Maintenance Manual