IBM 8187 Computer Hardware User Manual


 
Diagnostic Error Code FRU/Action
000-035-XXX
BIOS Reset Condition detected
1. Flash the system
2. System board
000-036-XXX
BIOS Register error
1. Flash the system
2. Boot block
3. System board
000-038-XXX
BIOS Extension failure
1. Flash the system
2. Adapter card
3. System board
000-039-XXX
BIOS DMI data error
1. Flash the system
2. System board
000-195-XXX
BIOS Test aborted by user
1. Information
2. Re-start the test, if necessary
000-196-XXX
BIOS test halt, error threshold exceeded
1. Press F3 to review the log file
2. Re-start the test to reset the log file
000-197-XXX
BIOS test warning
1. Make sure the component that is called
out is connected and/or enabled
2. Re-run test
3. Component that is called out in warning
statement
4. Component under test
000-198-XXX
BIOS test aborted
1. If a component is called out, make sure
it is connected and/or enabled
2. Flash the system and re-test
3. Go to “Undetermined problems” on page
109.
000-199-XXX
BIOS test failed, cause unknown
1. Go to “Undetermined problems” on
page 109.
2. Flash the system and re-test
3. Replace component under function test
000-250-XXX
BIOS APM failure
1. Flash the system
2. System board
000-270-XXX
BIOS ACPI failure
1. Flash the system
2. System board
001-000-XXX
System Test Passed
No action
001-00X-XXX
System Error
System board
001-01X-XXX
System Error
System board
001-024-XXX
System Addressing test failure
System board
001-025-XXX
System Checksum Value error
1. Flash the system
2. System board
Chapter 7. Symptom-to-FRU Index 71