IBM 8192 Computer Hardware User Manual


 
POST Error Code FRU/Action
662 Configuration Change has occurred Diskette drive configuration error or wrong
diskette drive type; run Setup.
6XX
Not listed above
1. Diskette Drive
2. System Board
3. Riser card
4. External Drive Adapter
5. Diskette Drive Cable
6. Power Supply
762
Math coprocessor configuration error
1. Run Setup.
2. Processor
3. System Board
7XX
Not listed above
1. Processor
2. System Board
962
Parallel port configuration error
1. Run Setup.
2. Parallel Adapter (if installed)
3. System Board
9XX
1. Printer
2. System Board
1047 16-Bit AT
Fast SCSI Adapter
107X
Check SCSI terminator installation
1. Check SCSI terminator installation
2. SCSI Cable
3. SCSI Terminator
4. SCSI Device
5. SCSI Adapter
1101
Serial connector error, possible system board
failure
Run Enhanced Diagnostics
1101, 1102, 1106, 1108, 1109
1. System Board
2. Any Serial Device
1107
1. Communications Cable
2. System Board
1102
Card selected feedback error
Run Enhanced Diagnostics
1103
Port fails register check
1. Run Enhanced Diagnostics
2. System Board
1106
Serial option cannot be turned off
1. Run Enhanced Diagnostics
2. System Board
1107
1. Serial Device Cable
2. System Board
1110
Register test failed
1. Run Enhanced Diagnostics
2. System Board
1116
Interrupt error
Run Enhanced Diagnostics
96 Hardware Maintenance Manual