IBM A40 TYPE 6840 Personal Computer User Manual


 
Diagnostic Error Code FRU/Action
000-197-XXX
BIOS test warning
1. Make sure the component that is called
out is connected and/or enabled
2. Re-run test
3. Component that is called out in warning
statement
4. Component under test
000-198-XXX
BIOS test aborted
1. If a component is called out, make sure
it is connected and/or enabled
2. Flash the system and re-test
3. Go to the Undetermined problems
section
000-199-XXX
BIOS test failed, cause unknown
1. Go to the Undetermined problems
section
2. Flash the system and re-test
3. Replace component under function test
000-250-XXX
BIOS APM failure
1. Flash the system
2. System board
000-270-XXX
BIOS ACPI failure
1. Flash the system
2. System board
001-000-XXX
System Test Passed
1. No action
001-00X-XXX
System Error
1. System board
001-01X-XXX
System Error
1. System board
001-024-XXX
System Addressing test failure
1. System board
001-025-XXX
System Checksum Value error
1. Flash the system
2. System board
001-026-XXX
System FLASH data error
1. Flash the system
2. System board
001-027-XXX
System Configuration/Setup error
1. Run Setup
2. Flash the system
3. System board
001-032-XXX
System Device Controller failure
1. System board
001-034-XXX
System Device Buffer Allocation failure
1. Reboot the system
2. Flash the system
3. Run memory test
4. System board
001-035-XXX
System Device Reset condition detected
1. System board
001-036-XXX
System Register error
1. System board
40 Hardware Maintenance Manual A40 Type 6840 A40P Type 6841 A40i Type 2271: IBM NetVista Computer