IBM AT-FS202SC/FS1 Switch User Manual


 
AT-FS20x Series Installation Guide
13
Note
See “Fiber Optic Port Specifications” on page 22 for additional
information on the fiber optic port.
AT-FS202 50/125 or 62.5/
125 micron
multimode
2 km (1.2 mi) 13 dB at 1310 nm
AT-FS202SC/FS1 50/125 or 62.5/
125 multimode
2 km (1.2 mi) 13 dB at 1310 nm
9/125 micron
single-mode
15 km (9.3 mi) 16 dB at 1310 nm
AT-FS202SC/FS2 9/125 micron
single-mode
40 km (24.8 mi) 30 dB at 1310 nm
AT-FS202SC/FS3 9/125 micron
single-mode
75 km (46.5 mi) 33 dB at 1310 nm
AT-FS202SC/FS4
2
9/125 micron
single-mode
100 km (62 mi) 34 dB at 1550 nm
1. Maximum distance for 100 Mbps optical datalinks is dependent on the following factors: type of optical
fiber, duplex mode of both end-nodes, and maximum optical loss budget for each of the optical fiber at
the operating optical wavelength.
2. The cable must be non-dispersion-shifted, dispersion-shifted, or non-zero dispersion-shifted
single-mode fiber optic cable.
Model Cable Type
Maximum
Operating
Distance
1
Maximum
Allowable Loss
Budget