STOp
stops the driver on the ordinal number specified.
STAT
queries the status of the ordinal number specified.
FIleadd
uses the address specified as the address of the ‘hot record’.
Note: The FILEADDR parameter overrides the FACID parameter.
FAcid
uses the FACE ID specified as the FACE ID of the ‘hot record’.
Ordinal
specifies number in Hex 0x00-0x13. If not specified, the default is 0.
All
runs the action with all 20 ordinals 0x00-0x13.
Note: The ALL parameter overrides the ORDINAL parameter.
Help
displays the correct syntax of the command.
Examples
The following example will start HOTR with all ordinals on I-stream two:
ZTEST 2 HOTR START ALL
The following example will start HOTR with ordinal 0 on I-stream one:
ZTEST HOTR START
The following example will query the status of HOTR with ordinal 0 on I-stream one:
ZTEST HOTR STAT
The following example will query the status of HOTR with all ordinals on I-stream three:
ZTEST HOTR STAT ALL
The following example will stop HOTR with ordinal 0 on I-stream one:
ZTEST HOTR STOP
The following example will stop HOTR with all ordinals on I-stream four:
ZTEST 4 HOTR STOP ALL