Installation Instructions
7.0 Installation Time
Note: To reduce the MES installation time it is recommended that you load the
Network Node Processor Code on the Service Processor and install the system
unit at the same time.
No impact on 3745 customer operations.
FFBM Machine Hrs. System Hrs. Nbr of CEs
10K8798 0.2 0.0 1
8.0 Tools/Material Required
None.
Installation (Steps 9-12)
9.0 Safety
Review the Safety Notices and the Safety Inspection Procedures located at the
beginning of the IBM 3745 Communication Controller All Models, IBM 3746
Expansion Unit Model 900, IBM 3746 Nways Multiprotocol Controller Model 950
Safety Information, GA33-0400.
10.0 Details of Installation
10.1 Installing and Connecting the NNP
Note: For any unexpected message or error concerning the NNP-B, go to the
chapter Problem Determination of the Network Node Processor Installation and
Maintenance (Based on 6578), GY27-0407.
1. Using the Network Node Processor Installation and Maintenance (Based
on 6578), GY27-0407, go to Chapter 1 and install the NNP following the
instructions to install a NNP-B. When completed go to next step.
2. Ask the customer for a maintenance window on 3746-900 with traffic deac-
tivated.
3746 PN 42L2445 EC F52322 EC F12701A EC F70078 EC F70110 EC H10024
FFBM 6 of 10 09 Oct 1998 14 DEC 1998 22 APR 1999 20 JAN 2000 08 MAR 2001
6