ID Tech 30 Computer Drive User Manual


 
Data Editing Command List
Enter Setup Mode /E/D/FJ<ENTER> Clear JX<ENTER>
Review Configuration JY<ENTER>
Exit Data Editing JZ<ENTER>
Delete Line JS<ENTER>
Data Editing JA<ENTER>
Enabled 1<ENTER>
Disabled 0<ENTER>
Unmatched Input JB<ENTER>
Do Not Send 0<ENTER>
Send 1<ENTER>
Code IDs JC<ENTER>
Enter JC<ENTER> and the default Code ID(s) from Code ID Definition
on page 29.
Set Length JD<ENTER>
Enter JD<ENTER>and two digits from the keyboard to indicate length.
Match String JE<ENTER>
Enter JE<ENTER>, one digit <ENTER> one digit <ENTER> for the start
position, and the string to match each character, followed by a <EN-
TER> (maximum 60 characters).
Count JF<ENTER>
Type JF<ENTER> and enter two digits from the keyboard to indicate
the next end of field, each followed by a <ENTER>.
Search String JG<ENTER>
Enter JG<ENTER> and enter characters for the search criteria from the
keyboard or function character chart, each character follo wed by a
<ENTER>.
Add Field JJ<ENTER>
Enter JJ<ENTER> and sequentially the characters to be included in the
new field from the keyboard or function character chart, each followed
by a <ENTER>.
42
43
Send Field Sequence JK<ENTER>
Enter JK<ENTER> and the field ID characters, each followed by
<ENTER> in the order to be sent (use upper case alphabetic charac-
ters).
Add Delay JM<ENTER>
Enter JM<ENTER> and two digits, each followed by a <ENTER> from
the keyboard. Each unit equals 100 milliseconds. Examples
Examples
EXAMPLE ONE
76440057320712
Symbology Code 128
Desired Output: Divide the input data record into two fields with one
consisting of the first six digits and the second containing the remain-
ing data. The output should have a <ENTER> inserted after each field.
Formula ID h C 06 A <ENTER> SEND ACBC
Field List Field A 764400
Field B 57320712
Field C <ENTER>
Keystroke Sequence
Enter Data Editing Setup /E/D/FJ
Enter Data Editing and Enable JA 1
Enter Track_ID and h (for Code 128) JC h
Enter Count and 06 JF 0<ENTER> 6<ENTER>
Enter Add Field and <ENTER> character JJ ^N<CR>
Enter Field Sequence and ACBC JKA<ENTER>C<
ENTER>B<CR>C<CR>
Enter Exit Setup JZ
Output Data 764400<ENTER>
57320712<ENTER>