IMC Networks E1 Network Card User Manual


 
3
Required CSU line Buildout (0db to -22db)
Receiver BOOST for T1 and E1 applications
Fiber transceivers must be for appropriate fiber run, i.e. (SM or MM)
Management location must be at HOST unit
Managed Modules
The IE-iMcV-T1/E1/J1-LineTerm, TP/SFP modules are installed as a HOST-REMOTE
pair and can be remotely managed when the HOST is installed in an iMediaChassis
with an SNMP Management module.
For a managed environment, first manually configure the desired features through
DIP Switch settings to ensure this configuration is maintained if management is ever
lost. After the module is installed, the SNMP enabled features for troubleshooting
can be modified by using the included iView
2
SNMP management software. Ensure
the software settings match the desired configuration requirements for the installation
as the chassis may maintain an old setting from a previous installation for that slot
location. Module Details will provide information such as serial number, date code
and part number. Please download the current SNMP firmware and iView
2
software
to ensure all functionality of the modules.
NOTE
If installing an IE-iMcV-T1/E1/J1-LineTerm, available in a fixed fiber transceiver model (series
850-141XX), as a Host and an IE-iMcV-T1/E1/J1-LineTerm with SFP and Configuration Control
(850-18100) as a Remote, connectivity will be established and data will pass. However, there
is no possibility of obtaining DDMI information of the SFP from the Remote end, since the
Host is not capable of it. If the Host and the Remote units are both IE-iMcV-T1/E1/J1-
LineTerm with SFP and Configuration Control, then the Host can extract DDMI information
from the SFP at the Remote end.