Function Command RW Min Max Default Step
RS-232 Communication / Network command table (continued)
Source 4
0: Computer in 1
1: Computer in 2
2: LAN
3: USB Type A
4: USB Type B
5: HDMI
6: Component
7: S-Video
8: Video
SR4 RW 0 8 8
Power-up Source
0: Computer in 1
1: Computer in 2
2: LAN
3: USB Type A
4: USB Type B
5: HDMI
6: Component
7: S-Video
8: Video
DSC RW 0 8 0
ADVANCED MENU: OPTION (SERVICE)
Auto Image Mode
0: Disable
1: Fast
2: Fine
SAI RW 0 2 1
Ghost Red GSR RW 118 138 128 1
Ghost Green GSG RW 118 138 128 1
Ghost Blue GSB RW 118 138 128 1
Reset Lamp Hours
1: reset
LRT W 0 1 n/a
Reset Filter Hours
1: reset
FRT W 0 1 n/a
Key Lock - Control Panel
0: Disable
1: Enable
KPE RW 0 1 0
Serial Port Echo
0: Disable
1: Enable
EC1 R 0 1 0
Factory Reset
0: not reset
1: reset
RST W 0 1 n/a
ADVANCED MENU: NETWORK
IP Address (1st octet) IP1 R 0 255
192
IP Address (2nd octet) IP2 R 0 255 168
IP Address (3rd octet) IP3 R 0 255 1
IP Address (4th octet) IP4 R 0 255 254