Intel BV80605001908AK Personal Computer User Manual


 
30Q4 INTEL PRODUCT GUIDE
Intel
®
Server Motherboards
Dual Socket Server Boards
Expansion Options I/O Specications - # of Ports
Model Code Name Release
EOL
Date Board Form Factor
Chassis
Form
Factor Socket
Max CPU
Embedded Option
Max TDP
# of DIMMs
Max Memory
Integ Grphx
# PCI Express Lanes
PCIe Gen3 x4
PCIe Gen3 x8
PCIe Gen3 x16
IO Exp Gen3 x8
PCIe Gen2 x4
PCIe Gen2 x8
PCIe Gen2 x16
IO Exp Gen2 x4
IO Exp Gen2 x8
PCIe Gen1 x1
PCIe Gen1 x8
IO Exp Gen1 x4
# USB
# SATA
RAID
# Serial
Integrated LAN
# LAN
# SAS
Embedded
USB SSD
Single
Part #
OEM Pack
Part #
BB = Bulk 10
pack
DB = Disty 5
pack
DUAL SOCKET SERVER BOARDS
S5520URT Urbanna Q1’09 Q4’13 SSI TEB-leveraged (12” x 13”) Rack LGA1366 2 Yes 130 W 12 192 GB Yes 3 1 1 5 6 0,1 2 Dual, GbE 2 S5520URT
S5520UR Urbanna Q1’09 Q4’13 SSI TEB-leveraged (12” x 13”) Rack LGA1366 2 Yes 130 W 12 192 GB Yes 3 1 1 5 6 0,1 2 Dual, GbE 2 BB5520URR
S5520HCT Hanlan Creek Q1’10 Q1’14 SSI EEB (12” x 13”) Pedestal LGA1366 2 No 130 W 12 192 GB Yes 3 1 1 8 6 0,1 2 Dual, GbE 2 S5520HCT
S5520HC Hanlan Creek Q1’09 Q4’13 SSI TEB-leveraged (12” x 13”) Pedestal LGA1366 2 Yes 130 W 12 192 GB Yes 3 1 1 4 6 0,1 2 Dual, GbE 2 S5520HCR BB5520HC
S5500HCV Hayden Valley Q2’09 Q4’13 SSI EEB (12” x 13”) Pedestal LGA1366 2 Yes 130 W 9 144 GB Yes 2 1 1 8 6 0,1 2 Dual, GbE 2 S5500HCVR BB5500HCVR
S2600CP2IOC Canoe Pass Q1’12 Q1’17 SSI EEB (12” x 13”) Pedestal Socket R 2 Yes 135 W 16 512 GB Yes 5 1 5 14 up to s/w 5 2 Dual, GbE 2 8 Yes DBS2600CP2IOC
S2600CP4IOC Canoe Pass Q1’12 Q1’17 SSI EEB (12” x 13”) Pedestal Socket R 2 Yes 135 W 16 512 GB Yes 5 1 5 14 up to s/w 5 2 Quad, GbE 4 8 Yes DBS2600CP4IOC
S2600CP2J Canoe Pass Q1’12 Q1’17 SSI EEB (12” x 13”) Pedestal Socket R 2 Yes 135 W 16 512 GB Yes 5 1 5 6 up to s/w 5 2 Dual, GbE 2 Yes BBS2600CP2J
S2600WPQ Washington Pass Q1’12 Q3’15 Custom (6.8’’ x 18.9’’) Rack Socket R 2 No 135 W 8 500 GB Yes 64 4 1 5 6 up to s/w 5 1 Dual, GbE 2 BBS2600WPQ
S2600WPF Washington Pass Q1’12 Q3’15 Custom (6.8’’ x 18.9’’) Rack Socket R 2 No 135 W 8 500 GB Yes 64 4 1 5 6 up to s/w 5 1 Dual, GbE 2 BBS2600WPF
S2600WP Washington Pass Q1’12 Q3’15 Custom (6.8’’ x 18.9’’) Rack Socket R 2 No 135 W 8 500 GB Yes 72 1 4 1 5 6 up to s/w 5 1 Dual, GbE 2 4 BBS2600WP
S2600JFQ Jefferson Pass Q1’12 Q2’15 Custom (6.42’’ x 17.7’’) Rack Socket R 2 No 135 W 8 250 GB Yes 48 3 1 5 6 up to s/w 5 1 Dual, GbE 3 4 BBS2600JFQ
S2600JFF Jefferson Pass Q1’12 Q3’15 Custom (6.42’’ x 17.7’’) Rack Socket R 2 No 135 W 8 250 GB Yes 48 3 1 5 6 up to s/w 5 1 Dual, GbE 2 4 BBS2600JFF
S2600JF Jefferson Pass Q1’12 Q2’15 Custom (6.42’’ x 17.7’)’ Rack Socket R 2 No 135 W 8 250 GB Yes 48 3 1 5 6 up to s/w 5 1 Dual, GbE 2 4 BBS2600JF
S2600IP4 Iron Pass Q1’12 Q1’17 Custom (14.2” x 15”)
Rack or
Pedestal
Socket R 2 Yes 135 W 16 500 GB Yes 6 1
1 1 5 4 up to s/w 5 2 Quad, GbE 4 8 Yes S2600IP4
S2600GZ Grizzly Pass Q1’12 Q1’15 Custom (16.5” x 16.5”) Rack FCLGA2011 2 Yes 130 W 24 768 GB Yes 2 6 1 7 10 up to s/w 5 2 Quad, GbE 4 Yes S2600GZ4 BBS2600GZ
S2600GL Grizzly Pass Q1’12 Q1’15 Custom (16.5” x 16.5”) Rack FCLGA2011 2 Yes 130 W 16 500 GB Yes 2 6 1 7 10 up to s/w 5 2 Quad, GbE 4 Yes S2600GL4 BBS2600GL
S2600CP4 Canoe Pass Q1’12 Q1’17 SSI EEB (12” x 13”) Pedestal Socket R 2 Yes 130 W 16 500 GB Yes 5 1 5 14 up to s/w 5 2 Quad, GbE 4 8 Yes S2600CP4 BBS2600CP4
S2600CP2 Canoe Pass Q1’12 Q1’17 SSI EEB (12” x 13”) Pedestal Socket R 2 Yes 130 W 16 500 GB Yes 5 1 5 14 up to s/w 5 2 Dual, GbE 2 8 Yes S2600CP2 BBS2600CP2
S2600COEIOC Copper Pass Q1’12 Q1’17 SSI EEB (12” x 13”) Pedestal Socket R 2 Yes 150 W 16 500 GB Yes 1 4 1 5 10 up to s/w 5 2 Quad, GbE 8 Yes DBS2600COEIOC
S2600COE Copper Pass Q1’12 Q1’17 SSI EEB (12” x 13”) Pedestal Socket R 2 Yes 150 W 16 500 GB Yes 84 1 4 1 5 10 up to s/w 5 2 Quad, GbE 4 8 Yes S2600COE BBS2600COE
S2600CO4 Copper Pass Q1’12 Q1’17 SSI EEB (12” x 13”) Pedestal Socket R 2 Yes 135 W 16 500 GB Yes 84 1 4 1 5 10 up to s/w 5 2 Quad, GbE 4 4 Yes S2600CO4 BBS2600CO4
S2400SC2
Swiftcurrent
Pass
Q2’12 Q2’15 SSI CEB (12” x 10.5”)
Rack or
Pedestal
Socket B2 2 No 95 W 8 128 GB Yes 1 1 1 1 4 6 s/w 0/1/10/5 2 2x 1GbE 2 0 Yes
BBS2400SC2
DBS2400SC2
S2400LP Lincoln Pass Q2’12 Q3’15 Custom (6.8” x 16.6”) Rack Socket B2 2 No 95 W 12 384 GB Yes 24 0 1 1 1 2 5 up to s/w 5 1 2x 1GbE 2 No BBS2400LP
S2400GP2 Granite Pass Q2’12 Q2’17 SSI EEB (12” x 13”) Pedestal Socket B2 2 No 95 W 6 384 GB Yes 2 1 2 1 4 6 s/w 0/1/10/5 2 2x 1GbE 2 Yes
BBS2400GP2
DBS2400GP2
S2400EP4 Eagle Pass Q2’12 Q2’17 SSI CEB (12” x 10.5”) Rack Socket B2 2 Yes 95 W 8 128 GB Yes 1 1 1 4 2 s/w 0/1/10/5 1 4x 1GbE 4 0 No DBS2400EP4
S2400EP2 Eagle Pass Q2’12 Q2’17 SSI CEB (12” x 10.5”) Rack Socket B2 2 Yes 95 W 8 128 GB Yes 1 1 1 4 2 s/w 0/1/10/5 1 2x 1GbE 2 0 No DBS2400EP2
S2400BB4 Black Bear Pass Q3’12 Q3’15 Custom (13.5” x 13.5”) Rack Socket B2 2 No 95 W 12 384 GB Yes 0 6 2 0 1 3 2 up to s/w 5 2 4x 1GbE 4 8 Yes S2400BB4