Intel SE7210TP1-E Computer Hardware User Manual


 
Troubleshooting
40 Intel Server Board SE7210TP1-E User Guide
LED Information
The Intel
®
Server Board SE7210TP1-E includes LEDs that can aid in troubleshooting your system.
A table of these LEDs with a description of their use is listed below.
LED Name Function Location Color Correction
ID Aid in server
identification from the
back panel
Front Panel and
board rear left
corner
Blue Press ID LED button or user
Server Management
software to turn off the LED.
System fault Visible fault warning Front panel and
board rear left
corner
Green or Amber
On = No Fault
Green Blink = degraded
Amber = critical error or
non-recoverable
Amber blink = non-critical
IDE activity Front panel Front panel and
board left side
Green Blinking = Activity. No action
required.
Memory fault
1–6
Identify failing memory
module
DIMM end front of
board
Amber On = Fault
POST code 1–4
(LSB, bit1, bit2,
MSB)
Display boot 80 POST
code
Left rear of board Each LED can be
Off, Green,
Amber, Red
See the POST code table
Fan Pack Fault Warn on fan failure Front center board Amber On = Fault
CPU 1 & 2 Fan
Fault
Identify fan failure Front center board Amber On = Fault
CPU 1 & 2
Fault
Identify processor failure 1” behind processor
socket
Amber On = Fault
5v Standby Identify 5v standby
power on state
Front left board Amber On = 5v standby power on
Power LED Identify the power state
of the system
Front Panel Green
Off = Power is off (off or
S5)
On = Power on or S0)
Slow Blink = Low power
state (S1 – S3)