Intermec PF2i Time Clock User Manual


 
48 EasyLAN Wireless Interface Kit Installation Instructions
Chapter 5 — Setup in IPL
3
/. Active channel and signal strength is shown in the printer’s display
window when the <i> key is pressed.
Active Channel
802.11b/g operates on a number of different channels, corresponding
to different frequencies. e printer scans for a suitable access point and
channel. e selected channel can be read from the printer. e read-
only setup-variable “CHANNEL” can assume values from 0 up to 14
depending on the region setting. 0 signifies that an association has not
yet been made, 1-14 is the currently selected channel.
<STX><SI>wt,CHANNEL<ETX>
Transmits current channel.
Access Point Information
e printer associates with an access point. e read-only setup-variable
“AP_MAC” will assume the MAC address of the access point which the
printer is currently associated with. If no association has been performed,
the value of “AP_MAC” is “00:00:00:00:00:00”.
<STX><SI>wt,AP_MAC<ETX>
Transmits the MAC address of the associated access point.
Signal Strength
An important tool when working out problems with wireless LANs
is a signal strength meter. e printer monitors the received signal
strength, and makes it available to the user. e read-only setup variable
“SIGNAL” assumes the value of the current received signal strength. e
value may vary from 0 (no signal) to 100 (maximum strength).
<STX><SI>wt,SIGNAL<ETX>
Transmits signal strength.
Speed
Depending on different (radio) network parameters—such as distribu-
tion of access points, frequencies, number of clients, etc.—the network
card may select a lower speed than the maximum for better overall per-
formance. e selected speed (rounded down to whole Mbps) can be
read from the printer. e read-only setup-variable “SPEED” can assume
values from 0 up to 54 (Mbps).