JVC SA-K51U Computer Drive User Manual


 
6 7
How to Mount
The following describes how to operate the front panel of the VR-510U to mount the SA-
K51U.
1.
Insert the plug into the plug socket and switch on the power switch of the VR-510U.
The MOUNT ERROR message is displayed on the monitor.
* It takes 10 to 20 seconds for the message to be displayed
after the power has been switched on.
* When the VR-510U is not receiving video input signals,
INPUT SIG ERROR and MOUNT ERROR messages are
displayed on the monitor alternatively.
2.
Simultaneously press the MENU button and the 4 button while holding down the STOP
button.
The MENU screen is displayed.
3.
Make sure FUNCTION-1 is selected and then return the shuttle dial to the SELECT
position by turning it either clockwise or anticlockwise.
The FUNCTION-1 screen is displayed.
3-10-02 SUN 18:03:38
AL------- --- %
MOUNT ERROR
[MENU] J.DIR
FUNCTION-1
FUNCTION-2
HOUR METER
EMERGENCY H ISTORY
OPERAT ION CHECK MODE
OPE VER. xx.xx
HDR VER. xx.xx
BOOT VER. xx.xx
SCSI VER. xx.xx
EXT.M VER. xx.xx
4.
Select 2.HDD MOUNT by turning the jog dial and then return the shuttle dial to the
SELECT position by turning it either clockwise or anticlockwise.
The jog operation switches from J.DIR to J.DIR +.
5.
Set to standard format (STD) or extended format (EXTN) by turning the jog dial.
Turning the jog dial switches between OFF STD EXTN
OFF in order.
Selects whether the hard disk is formatted with standard
or extended mode.
When the disk is formatted, all existing data on the hard
disk will be erased.
STD: Normally, use this position. Up to 13,000 alarm/
sensor events can be recorded.
EXTN: Set to this position if you want to be able to record
more than 13,000 alarm/sensor events (up to about
100,000 events).
* Extended formatting takes about 5 minutes to complete.
Recording time is shorter than with the standard format.
6.
Press the ¢ to start mounting.
During mounting MOUNT XX% is displayed on the monitor.
Numbers are displayed instead of XX to show the progress.
When mounting has finished the INPUT SIG ERROR and
MOUNT ERROR messages are displayed on the monitor
alternately. After approximately 10 to 20 seconds the
MOUNT ERROR message disappears and mounting is
complete.
[FUNCTION-1] J.DIR +
1.FACTORY SETTING OFF
2 . HDD MOUNT [ - - - - ] OFF
3.DIP SW-0 OFF
4.DIP SW-1 OFF
5.DIP SW-2 OFF
6.DIP SW-3 OFF
7.DIP SW-4 OFF
8.DIP SW-5 OFF
9.DIP SW-6 OFF
10.DIP SW-7 OFF
[FUNCTION-1] J.DIR +
1 . FACTORY SETT I NG OFF
2.HDD MOUNT [----] STD
3.DIP SW-0 OFF
4.DIP SW-1 OFF
5.DIP SW-2 OFF
6.DIP SW-3 OFF
7.DIP SW-4 OFF
8.DIP SW-5 OFF
9.DIP SW-6 OFF
10.DIP SW-7 OFF
3-10-02 SUN 18:05:21
AL------- --- %
MOUNT x x%
I NPUT S IG ERROR
[ FUNCT ION - 1 ] J . DI R
1.FACTORY SETTING OFF
2 . HDD MOUNT [ - - - - ] OFF
3.DIP SW-0 OFF
4.DIP SW-1 OFF
5.DIP SW-2 OFF
6.DIP SW-3 OFF
7.DIP SW-4 OFF
8.DIP SW-5 OFF
9.DIP SW-6 OFF
10.DIP SW-7 OFF