Specifi cations
AAC-3 CHASSIS
Dimensions (H x W x D): 13.95” x 17.32” x 19” (354.3 x 440 x 482.6 mm)
Weight: 60 lbs. (27 kg)
Mounting: Available for 19-inch or 23-inch standard equipment racks
Operating Temperature: 32º F to 104º F, ambient (0° C to 40° C)
Operating Humidity: 5% to 95%, non-condensing
AAC-2 AND CELLSMART 200 CHASSIS
Dimensions (H x W x D): 6.95” x 17.32” x 19” (176.5 x 440 x 482.6 mm)
Weight: 29 lbs. (13.2 kg)
Mounting: Available for 19-inch or 23-inch standard equipment racks
Operating Temperature: 32º F to 104º F, ambient (0° C to 40° C)
Operating Humidity: 5% to 95%, non-condensing
EMI/ESD/SAFETY
EMI: FCC Part 68, FCC Part 15, Class A, EN55022 Class B
Immunity: EN55024
Safety: UL1950, EN60950, CSA 22.2 No 950 - M95
NEBS: Level 3 certifi ed
SWITCHING BACKPLANE
Cell bus: Dynamic time-allocated, output buffered per port or connection
Maximum system throughput: 524 Mbps (1,168,000 cells/second)
Connections: 8192 VCCs, 512 VPCs, 512 Multicast
POWER SYSTEM
AAC-3: Dual redundant power system. Modular power supplies, fi eld replaceable with unit powered. Monitored with
alarms/traps on failure. Forced-air cooled. Supports mixed use of AC/DC power modules.
AAC-2 and CellSMART 200: Single power system. Modular power supply. Monitored with alarms/traps on failure.
Forced-air cooled. Supports use of AC/DC power modules.
AC power supply modules: 120/240 VAC (85 to 264 volts), 50/60Hz +/- 3Hz
DC power supply modules: -48 VDC (42 to 60 VDC)
MANAGEMENT ACCESS
Control port: VT100 via RS232 port on front panel (Additional RS232 port on the Integrated System Controller)
Ethernet port: SNMP or Telnet
In-band: SNMP or Telnet
Telnet sessions: Up to 4 concurrently with the Integrated System Controller
Common Modules
INTEGRATED SYSTEM CONTROLLER (ISC)
Clock sources: Internal reference oscillator or recovered from user-specifi ed physical port
Clock fallback: User-selectable primary and secondary clock source with automatic fallback and recovery
Internal reference: Oscillator Stratum 4 or better
Power loss protection: Loss of all input line power will not affect the confi guration settings; performance data will
be maintained for 12 hours upon loss of power
Alarm: Critical, Major, and Minor alarm indicators are viewable from the rear
Contact closure for audible and visual alarms
ACO (Automatic Cut Off) button disables audible alarms
Confi guration backup: Pluggable Type II compact fl ash
Management access: Ethernet port and DTE asynchronous port for dial-up modem (in addition to front panel port)